Mostrar el registro sencillo del ítem

dc.contributor.authorCordero Grande, Lucilio
dc.contributor.authorRoyuela del Val, Javier
dc.contributor.authorSanz Estébanez, Santiago Rodrigo 
dc.contributor.authorMartín Fernández, Marcos Antonio 
dc.contributor.authorAlberola López, Carlos 
dc.date.accessioned2015-12-21T11:25:58Z
dc.date.available2015-12-21T11:25:58Z
dc.date.issued2015
dc.identifier.citationMedical Image Analysis (en prensa)es
dc.identifier.urihttp://uvadoc.uva.es/handle/10324/15156
dc.description.abstractThe purpose of this work is to develop a method for direct estimation of the cardiac strain tensor by extending the harmonic phase reconstruction on tagged magnetic resonance images to obtain more precise and robust measurements. The extension relies on the reconstruction of the local phase of the image by means of the windowed Fourier transform and the acquisition of an overdetermined set of stripe orientations in order to avoid the phase interferences from structures outside the myocardium and the instabilities arising from the application of a gradient operator. Results have shown that increasing the number of acquired orientations provides a signi cant improvement in the reproducibility of the strain measurements and that the acquisition of an extended set of orientations also improves the reproducibility when compared with acquiring repeated samples from a smaller set of orientations. Additionally, biases in local phase estimation when using the original harmonic phase formulation are greatly diminished by the one here proposed. The ideas here presented allow the design of new methods for motion sensitive magnetic resonance imaging, which could simultaneously improve the resolution, robustness and accuracy of motion estimates.es
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectTagged Magnetic Resonance Imaginges
dc.subjectHarmonic Phase Reconstructiones
dc.subjectArtifactses
dc.subjectStrain Tensores
dc.subjectWindowed Fourier Transformes
dc.titleMulti-Oriented Windowed Harmonic Phase Reconstruction for Robust Cardiac Strain Imaginges
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doidoi:10.1016/j.media.2015.12.001es
dc.peerreviewedSIes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem