Por favor, use este identificador para citar o enlazar este ítem:http://uvadoc.uva.es/handle/10324/25390
Título
Optimization and monitoring of two pilots plants: a mesophilic anaerobic digester and urine diversion toilets in a context of source separation wastewater management
Autor
Director o Tutor
Año del Documento
2017
Titulación
Grado en Ingeniería Química
Zusammenfassung
Productos químicos y farmacéuticos están generalizados en la vida cotidiana
y son recuperados en plantas de aguas (WWTP) donde sus tratamientos son
caros, con alto requerimiento energético y no suficientemente efectivos, debido
a las altas diluciones de las plantas. 65% de los microcontaminantes estudiados
son encontrados en la orina, representan el 1% del residuo entrante. La
separación en la fuente empieza con la evaluación de váteres separativos (UDT).
El prototipo basado en EVAC con tecnología de vacío es comparado con el
comercializado UDT, Wostman con sistema por gravedad. La dilución de la orina
obtenida es 79,4% (Wostamn) frente al 3,3% (prototipo), valor adecuado para
futuros tratamientos pero aún presenta problemas de aceptabilidad en los
usuarios.
Estudio previo a la degradación de microcontaminantes, la eficiencia de un
reactor anaerobio mesophilico (35ºC) tras 100 días alimentado con el efluente
de WWTP presenta 58,6% en eliminación de DCO y en potencial metanogénico
54,6%. Abstract:
Chemical and pharmaceutical products are ubiquitous in everyday life and
recovered in wastewater plants where treatments are not effectives enough,
expensive and high energy cost, partly because of the huge dilutions of the
plants. 65% of the micropollutants studied are found in urine, which represents
less of 1% volume in sewage water. Consequently, source separation starts with
the evaluation of a urine diversion toilet (UDT). Prototype based on EVAC with
vacuum technology is compared to a commercialized Wostman with gravity
system. Dilution of urine obtained in Wostman is 79.4% against 3.30% in
prototype which represents an adequate value for further treatments but it is not
enough enhanced concerning to users acceptance (cleaning and maintenance).
Efficiency of a mesophilic (35ºC) anaerobic digester fed with WWTP effluent
was evaluated as previous step to degradation of micropollutans analyzes. After
100 days, removal of COD obtained is 58.6 % and methane yield is 54.6%.
Materias (normalizadas)
Ingeniería química
Medicamentos - Análisis
Departamento
Departamento de Ingeniería Química y Tecnología del Medio Ambiente
Idioma
eng
Derechos
openAccess
Aparece en las colecciones
- Trabajos Fin de Grado UVa [30475]
Dateien zu dieser Ressource
Solange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Attribution-NonCommercial-NoDerivatives 4.0 International