dc.contributor.author | Martín Ramos, Pablo | |
dc.contributor.author | Palacios Jaimes, Gloria Yaneth | |
dc.contributor.author | Rey Martínez, Francisco Javier | |
dc.contributor.author | Alonso Fernández-Coppel, Ignacio | |
dc.date.accessioned | 2017-09-11T10:28:08Z | |
dc.date.available | 2017-09-11T10:28:08Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | International Journal of Photo energy, open access 2017 | es |
dc.identifier.uri | http://uvadoc.uva.es/handle/10324/25490 | |
dc.description | Producción Científica | es |
dc.description.abstract | The EU Energy Performance of Buildings Directive (Directive 2010/31/EU) poses a major challenge, as it promotes the transformation of existing buildings into Nearly Zero‐Energy Buildings (NZEB). In this work we present the case of study of a lecture hall building, owned by the University of Valladolid (Spain), that is currently being refurbished into a NZEB by integration of Renewable Energy Sources (RES), also in line with the requirements from Directive 2009/28/EC. As part of its major renovation, not only Trombe walls and geothermal energy are to be incorporated, but also a building integrated solar photovoltaic (BIPV) system to address the electricity needs and reduce the building’s energy use and GHGs in a cost-effective manner. The environmental profile of this BIPV system has been investigated using life-cycle impact assessment (LCIA), assessing the net emissions of CO2 and the damages caused in a comparative context with conventional electricity-generation pathways. In spite of the small power installed in this first stage (designed to cover only an annual energy consumption of ca. 13000 kWh, around 6% of the total demand), it can be concluded that significant environmental benefits are gained using this system. Keywords: Building Integrated Photovoltaics (BIPV); Environmental Impacts; Life Cycle Assessment (LCA); Life Cycle Impact Assessment (LCIA); Nearly Zero Energy Building (NZEB). | es |
dc.format.mimetype | application/pdf | es |
dc.language.iso | eng | es |
dc.publisher | International Journal of Photo energy | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.title | Transformation of a University lecture hall in Valladolid (Spain) into a NZEB: LCA of a BIPV system integrated in its façade | es |
dc.type | info:eu-repo/semantics/article | es |
dc.peerreviewed | SI | es |
dc.description.project | The authors would like to gratefully ackowledge the financial support by Consejería de Educación de la Junta de Castilla y León through project number VA029U16. | es |
dc.rights | Attribution 4.0 International |