dc.identifier.urihttp://uvadoc.uva.es/handle/10324/40280
dc.description.abstractLa radioterapia es uno de los tratamientos empleados para combatir el cáncer, se caracteriza por tener una gran eficiencia y ser poco invasiva. Para la realización de estas terapias se usan máquinas de una elevada precisión, los aceleradores lineales de electrones. A pesar de la gran precision que presentan este tipo de máquinas, los planificadores encargados de modelizar la trayectoria de los haces y calcular su comportamiento presentan problemas con campos pequeños. Antes de realizar un tratamiento es necesario comparar los cálculos del planificador con medidas reales, para campos grandes se realizan con cámaras de ionización, pero para campos pequeños las medidas realizadas con la cámara no son fiables. Este Trabajo de Fin de Grado pretende exponer como validar los calculos de esos campos pequeños realizados por el planificador. Se han realizado medidas de campos pequeños con películas radiocrómicas (PRC) que carecen de las limitaciones de las cámaras y se han comparado con los cálculos del planificador; observando los tamaños límite de los campos para la realización de tratamientos adecuados.es
dc.description.abstractRadiotherapy is one of the treatments used to fight cancer, it is characterized by having a high efficiency and being minimally invasive. For the realization of these therapies, high accuracy machines are used, the linear accelerators of electrons. In spite of the great precision that this type of machines presents, the planners in charge of modeling the path of the beams and calculating their behavior present problems with small fields. Before carrying out a treatment it is necessary to compare the calculations of the planner with real measurements, for large fields are made with ionization chambers, but for small fields the measurements made with the camera are not reliable. This Final Degree Project aims to show how to validate those small fields made by the planner. Measurements of small fields with radiochromic films (PRC) have been made that lack the limitations of the cameras and have been compared with the calculations of the planner; observing the limit sizes of the fields for the realization of suitable treatments.es
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.classificationRadioterapiaes
dc.subject.classificationPelículas radiocrómicases
dc.titleValidación con película radiocrómica (PRC) de un planificador de radioterapia para campos pequeñoses
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.description.degreeGrado en Físicaes