• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Ricerca

    Tutto UVaDOCArchiviData di pubblicazioneAutoriSoggettiTitoli

    My Account

    Login

    Estadísticas

    Ver Estadísticas de uso

    Compartir

    Mostra Item 
    •   UVaDOC Home
    • PRODUZIONE SCIENTIFICA
    • Departamentos
    • Dpto. Ingeniería Eléctrica
    • DEP45 - Artículos de revista
    • Mostra Item
    •   UVaDOC Home
    • PRODUZIONE SCIENTIFICA
    • Departamentos
    • Dpto. Ingeniería Eléctrica
    • DEP45 - Artículos de revista
    • Mostra Item
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/53287

    Título
    A study of the effects of time aggregation and overlapping within the framework of IEC standards for the measurement of harmonics and interharmonics
    Autor
    Arranz Gimón, Ángel EugenioAutoridad UVA
    Zorita Lamadrid, Ángel LuisAutoridad UVA Orcid
    Moríñigo Sotelo, DanielAutoridad UVA Orcid
    Duque Pérez, ÓscarAutoridad UVA Orcid
    Año del Documento
    2019
    Editorial
    MDPI
    Descripción
    Producción Científica
    Documento Fuente
    Applied Sciences, 2019, vol. 9, n. 21, 4549
    Abstract
    The increasing incorporation of power electronics and other non-linear loads, in addition to their energy advantages, also implies a poor power quality, especially as regards harmonic pollution. Different solutions have been proposed to measure harmonic content, taking the International Electrotechnical Commission (IEC) standards as a reference. However, there are still some issues related to the measurement of the harmonic, and especially, interharmonic content. Some of those questions are addressed in this work, such as the problem derived from the instability of the values obtained by applying the discrete Fourier transform to each sampling window, or the appearance of local peaks when there are tones separated by multiples of the resolution. Solutions were proposed based on time aggregation and the overlapping of windows. The results demonstrate that aggregation time, window type, and overlapping can improve the accuracy in harmonic measurement using Fourier transform-based methods, as defined in the standards. The paper shows the need to consider spectral and time groupings together, improving results by using an appropriate percentage of overlap and an adaptation of the aggregation time to the harmonic content.
    Palabras Clave
    Harmonics
    Armónicos
    Interharmonics
    Interarmónicos
    ISSN
    2076-3417
    Revisión por pares
    SI
    DOI
    10.3390/app9214549
    Version del Editor
    https://www.mdpi.com/2076-3417/9/21/4549
    Propietario de los Derechos
    © 2019 The Authors
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/53287
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Aparece en las colecciones
    • DEP45 - Artículos de revista [44]
    Mostra tutti i dati dell'item
    Files in questo item
    Nombre:
    Study-effects-time-aggregation.pdf
    Tamaño:
    5.205Mb
    Formato:
    Adobe PDF
    Thumbnail
    Mostra/Apri
    Atribución 4.0 InternacionalLa licencia del ítem se describe como Atribución 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10