Mostrar el registro sencillo del ítem

dc.contributor.authorCisnal de la Rica, Ana
dc.contributor.authorIhmig, Frank R.
dc.contributor.authorFraile Marinero, Juan Carlos 
dc.contributor.authorPérez Turiel, Javier 
dc.contributor.authorMuñoz Martinez, Victor
dc.date.accessioned2022-10-07T12:50:53Z
dc.date.available2022-10-07T12:50:53Z
dc.date.issued2019
dc.identifier.citationSensors, 2019, vol. 19, n. 12, 2725es
dc.identifier.issn1424-8220es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/55896
dc.descriptionProducción Científicaes
dc.description.abstractDepending on their use, electrodes must have a certain size and design so as not to compromise their electrical characteristics. It is fundamental to be aware of all dependences on external factors that vary the electrochemical characteristics of the electrodes. When using implantable electrodes, the maximum charge injection capacity (CIC) is the total amount of charge that can be injected into the tissue in a reversible way. It is fundamental to know the relations between the characteristics of the microelectrode itself and its maximum CIC in order to develop microelectrodes that will be used in biomedical applications. CIC is a very complex measure that depends on many factors: material, size (geometric and effectiveness area), and shape of the implantable microelectrode and long-term behavior, composition, and temperature of the electrolyte. In this paper, our previously proposed measurement setup and automated calculation method are used to characterize a graphene microelectrode and to measure the behavior of a set of microelectrodes that have been developed in the Fraunhofer Institute for Biomedical Engineering (IBMT) labs. We provide an electrochemical evaluation of CIC for these microelectrodes by examining the role of the following variables: pulse width of the stimulation signal, electrode geometry and size, roughness factor, solution, and long-term behavior. We hope the results presented in this paper will be useful for future studies and for the manufacture of advanced implantable microelectrodes.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherMDPIes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.classificationGraphene microelectrodeses
dc.subject.classificationMicroelectrodos de grafenoes
dc.titleApplication of a novel measurement setup for characterization of graphene microelectrodes and a comparative study of variables influencing charge injection limits of implantable microelectrodeses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2019 The Authorses
dc.identifier.doi10.3390/s19122725es
dc.relation.publisherversionhttps://www.mdpi.com/1424-8220/19/12/2725es
dc.peerreviewedSIes
dc.description.projectMinisterio de Economía, Industria y Competitividad (project DPI2016-80391-C3-3-R)es
dc.rightsAtribución 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem