• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo UVaDOCComunidadesPor fecha de publicaciónAutoresMateriasTítulos

    Mi cuenta

    Acceder

    Estadísticas

    Ver Estadísticas de uso

    Compartir

    Ver ítem 
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Química Analítica
    • DEP60 - Artículos de revista
    • Ver ítem
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Química Analítica
    • DEP60 - Artículos de revista
    • Ver ítem
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/57788

    Título
    Amperometric biosensor for oxalate determination in urine using sequential injection analysis
    Autor
    Rodríguez, José Antonio
    Hernández, Prisciliano
    Salazar Pereda, Verónica
    Castrillejo Hernández, María YolandaAutoridad UVA Orcid
    Barrado Esteban, EnriqueAutoridad UVA Orcid
    Año del Documento
    2012
    Editorial
    MDPI
    Descripción
    Producción Científica
    Documento Fuente
    Molecules, 2012, vol. 17, n. 8, p. 8859-8871
    Resumen
    An amperometric flow biosensor for oxalate determination in urine samples after enzymatic reaction with oxalate oxidase immobilized on a modified magnetic solid is described. The solid was magnetically retained on the electrode surface of an electrode modified with Fe (III)-tris-(2-thiopyridone) borate placed into a sequential injection system preceding the amperometric detector. The variables involved in the system such as flow rate, aspired volumes (modified magnetic suspension and sample) and reaction coil length were evaluated using a Taguchi parameter design. Under optimal conditions, the calibration curve of oxalate was linear between 3.0–50.0 mg·L−1, with a limit of detection of 1.0 mg·L−1. The repeatability for a 30.0 mg·L−1 oxalate solution was 0.7%. The method was validated by comparing the obtained results to those provided by the spectrophotometric method; no significant differences were observed.
    Materias Unesco
    23 Química
    2301 Química Analítica
    Palabras Clave
    Oxalate
    Urine
    Sequential injection analysis
    Magnetic particles
    ISSN
    1420-3049
    Revisión por pares
    SI
    DOI
    10.3390/molecules17088859
    Patrocinador
    CONACyT (Project 178607)
    Ministerio de Ciencia e Innovación (MCINN AN2010-00234)
    Junta de Castilla y León (Project VA023A10-2)
    Version del Editor
    https://www.mdpi.com/1420-3049/17/8/8859
    Propietario de los Derechos
    © 2012 The Author(s)
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/57788
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Aparece en las colecciones
    • DEP60 - Artículos de revista [112]
    Mostrar el registro completo del ítem
    Ficheros en el ítem
    Nombre:
    Amperometric-biosensor-oxalate.pdf
    Tamaño:
    697.1Kb
    Formato:
    Adobe PDF
    Thumbnail
    Visualizar/Abrir
    Attribution 3.0 UnportedLa licencia del ítem se describe como Attribution 3.0 Unported

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10