Mostrar el registro sencillo del ítem
dc.contributor.advisor | López Cabeceira, Ana Cristina | es |
dc.contributor.advisor | Gómez Incio, Mónica | es |
dc.contributor.author | Aceituno Muriel, Andrea | |
dc.contributor.editor | Universidad de Valladolid. Facultad de Ciencias | es |
dc.date.accessioned | 2023-01-16T08:47:06Z | |
dc.date.available | 2023-01-16T08:47:06Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | https://uvadoc.uva.es/handle/10324/58256 | |
dc.description.abstract | La Radioterapia es una de las áreas de actividad sanitaria en la que participan los especialistas en Radiofísica Hospitalaria. Los Físicos Médicos junto a los Oncólogos Radioterápicos y Técnicos en Dosimetría y Radioterapia se responsabilizan, entre otros trabajos, de llevar a cabo los tratamientos de pacientes oncológicos. La realización de dichos tratamientos consta de tres etapas: adquisición de imágenes, planificación y verificación del tratamiento. El objetivo de este Trabajo Fin de Grado es la puesta en marcha y caracterización de un equipo de dosimetría que se emplearía, en una primera etapa, como parte del proceso de verificación de tratamientos en el que se trata de comprobar que los cálculos realizados por el TPS coincide con la radiación dada por el LINAC. Para ello se irradiaron varias planificaciones de distintos pacientes sobre las películas radiocrómicas y, mediante el análisis gamma, realizar la comparación entre el plan de dosis exportado desde el TPS y dicha película. Realizamos este estudio sobre tres pacientes planificados mediante las técnicas 3D, VMAT y un campo cuadrado, respectivamente. | es |
dc.description.abstract | Radiotherapy is one of the areas of healthcare activity in which Hospitalary Specialists in Radiophysics participate. Medical Physicists, Radiation Oncologists and Radiotherapy and Dosimetry Technicians carry out, among other works, the treatments of oncology patients. The implementation of these treatments consists of three stages: image acquisition, treatment planning and verification. The objective of this Final Degree Project is the implementation and characterization of the dosimetric equipment that will be used, at an initial stage, as part of the treatment verification process that is based on checking that the treatment plan calculated by the TPS coincides with the radiation given by the LINAC. To do this, we are going to irradiate the plan of diferent patients into the radiochromic film and, through the gamma analysis, the comparison between the dose plan exported by the TPS and such film is carried out. We are going to conduct this study about three patients that are planned using 3D, VMAT and square field techniques, respectively. | es |
dc.description.sponsorship | Departamento de Electricidad y Electrónica | es |
dc.format.mimetype | application/pdf | es |
dc.language.iso | spa | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject.classification | Oncología Radioterápica | es |
dc.subject.classification | LINAC | es |
dc.subject.classification | Película radiocrómica | es |
dc.title | Caracterización de un equipo de dosimetría con película radiocrómica y verificación del Sistema de Planificación Monaco 5.51.02 (Elekta) | es |
dc.type | info:eu-repo/semantics/bachelorThesis | es |
dc.description.degree | Grado en Física | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
- Trabajos Fin de Grado UVa [29752]
La licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional