| dc.contributor.advisor | Moreau Ortega, Alejandro | es |
| dc.contributor.advisor | Paredes Mendez, Xavier | es |
| dc.contributor.author | Liébana Sendino, Victor | |
| dc.contributor.editor | Universidad de Valladolid. Escuela de Ingenierías Industriales | es |
| dc.date.accessioned | 2023-08-31T11:06:34Z | |
| dc.date.available | 2023-08-31T11:06:34Z | |
| dc.date.issued | 2023 | |
| dc.identifier.uri | https://uvadoc.uva.es/handle/10324/61284 | |
| dc.description.abstract | El impacto medioambiental de los refrigerantes ha obligado a buscar alternativas
que no dañen la capa de ozono, regulado desde la Cumbre de Montreal, ni generen
altas emisiones de gases de efecto invernadero, regulado por el Protocolo de Kioto.
El reto de estos nuevos refrigerantes es conseguir un buen rendimiento generando
el mínimo impacto en el medioambiente. Se ha comparado el rendimiento, las
propiedades de idoneidad, los parámetros tecno-económicos y el impacto
medioambiental de cuatro refrigerantes convencionales que están presentes en el
mercado con una nueva mezcla patentada en condiciones de climatización
doméstica y de refrigeración industrial, ambos casos en verano e invierno. Los cuatro
refrigerantes convencionales que se utilizan como comparación con la nueva mezcla
refrigerante son dióxido de carbono y amoniaco como fluidos refrigerantes naturales,
y R-1234ze y R-454C como fluidos refrigerantes antropogénicos. Se demuestra que
la mezcla patentada es una buena alternativa en climatización doméstica en
invierno. | es |
| dc.description.abstract | The environmental impact of refrigerants has forced the search for alternatives that
do not damage the ozone layer, regulated since the Montreal Summit, or generate
high greenhouse gas emissions, regulated by the Kyoto Protocol. The challenge of
these new refrigerants is to achieve good performance while generating the minimum
impact on the environment. The performance, suitability properties, techno-economic
parameters and environmental impact of four conventional refrigerants currently on
the market have been compared with a new proprietary blend under domestic air
conditioning and industrial refrigeration conditions, both in summer and winter
conditions. The four conventional refrigerants used as a comparison with the new
refrigerant blend are carbon dioxide and ammonia as natural refrigerant fluids, and
R-1234ze and R-454C as anthropogenic refrigerant fluids. It is shown that the
proprietary blend is a good alternative in domestic air conditioning in winter. | en |
| dc.description.sponsorship | Departamento de Ingeniería Energética y Fluidomecánica | es |
| dc.format.mimetype | application/pdf | es |
| dc.language.iso | spa | es |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject.classification | Refrigerantes | es |
| dc.subject.classification | Operación | es |
| dc.subject.classification | Ciclos | es |
| dc.subject.classification | Simulación | es |
| dc.subject.classification | Comparativa | es |
| dc.title | Evaluación comparativa de un nuevo gas refrigerante patentado frente a cuatro convencionales en condiciones reales de operación domésticas e industriales | es |
| dc.type | info:eu-repo/semantics/bachelorThesis | es |
| dc.description.degree | Grado en Ingeniería en Tecnologías Industriales | es |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.subject.unesco | 2204.05 Gases | es |