dc.description.abstractThe goal of this study was to analyze the agreement between the Medmont E300 and the Visionix VX120+ systems in terms of non-invasive tear break-up time (NIBUT) and tear meniscus height (TMH) measurements. A total of 60 eyes (30 healthy subjects) were enrolled. NIBUT and TMH were evaluated with Medmont E300; first NIBUT, NIBUT50%, and TMH were evaluated with Visionix VX120+. Both evaluations were performed in a random order by the same clinician for right, left, and both eyes. The Medmont E300 provided significantly higher NIBUT than Visionix VX120+ for first NIBUT in right, left, and both eyes (p ≤ 0.003) and NIBUT50% in left and both eyes (p ≤ 0.042). The TMH measured with VX120+ was significantly higher than with Medmont E300 considering both eyes (p = 0.037). No significant correlations were found between both devices for either NIBUT (p ≥ 0.11) or TMH (p ≥ 0.09). Passing–Bablok regression analyses revealed poor agreement between devices for NIBUT and TMH outcomes. VX120+ is expected to provide substantial lower first NIBUT values than the NIBUT measured by Medmont E300. Clinicians should consider not using both instruments as interchangeable for dry eye diagnosis.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherMDPIes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectEye - Diseases - Treatmentes
dc.subjectOjo - Enfermedades y defectos - Tratamientoes
dc.subjectDry eye syndromeses
dc.subjectSíndrome de ojo secoes
dc.subjectOphthalmologyes
dc.subjectMaterials sciencees
dc.subjectCiencia de los materiales
dc.subjectMedical technology
dc.titleAgreement of tear break-up time and meniscus height between Medmont E300 and Visionix VX120+es
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2022 The Authorses
dc.identifier.doi10.3390/app12094589es
dc.relation.publisherversionhttps://www.mdpi.com/2076-3417/12/9/4589es
dc.identifier.publicationfirstpage4589es
dc.identifier.publicationissue9es
dc.identifier.publicationtitleApplied Scienceses
dc.identifier.publicationvolume12es
dc.peerreviewedSIes
dc.description.projectMinisterio de Economía, Industria y Competitividad - (project RYC-2016-20471)es
dc.identifier.essn2076-3417es
dc.rightsAtribución 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones
dc.subject.unesco32 Ciencias Médicases
dc.subject.unesco3201.09 Oftalmologíaes
dc.subject.unesco3314 Tecnología Médicaes


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem