Mostrar el registro sencillo del ítem

dc.contributor.authorMartínez García, María del Carmen 
dc.contributor.authorMar Sardaña, Santiago
dc.contributor.authorBlanco Mezquita, José Tomás
dc.contributor.authorTorres, R.M.
dc.contributor.authorMerayo Lloves, Jesús
dc.date.accessioned2014-10-08T08:53:14Z
dc.date.available2014-10-08T08:53:14Z
dc.date.issued2009
dc.identifier.citationJournal of Modern Optics, May 2009, vol. 56, n.8. p.1014-1021es
dc.identifier.issn0950-0340es
dc.identifier.urihttp://uvadoc.uva.es/handle/10324/6472
dc.descriptionProducción Científicaes
dc.description.abstractThe aim of this work is to provide experimental data for corneal transparency and scattering to help create a more complete model of corneal transparency. The scattered light in 96 healing hen corneas was measured for three wavelengths by a scatterometer constructed in the Optics Laboratory (The University of Valladolid, Spain). With the help of mirrors and beamsplitters, the light from the three lasers is directed toward the cell containing the sample to be measured. The measured scattered light varies between six orders of magnitude. Corneal transmissivity, mean cosine of a scattering angle, and angular distribution of scattered light were all computed. The total transmitted light remained practically constant over a wide range of light values transmitted in a forward direction (direct transmissivity). The value of the mean cosine of the scattering direction is very close to the unit (g40:98), even in corneas with high opacities. The behavior of g indicates that even damaged corneas evidence extremely small scattering, compared to other biological tissues. The transmission reduction of each cornea is related to an increase in scattered light. In all cases, scattered light is concentrated at very small angles. This behavior is acceptable in corneas that are healthy or which evidence small lesions, but remains in corneas that are severely injured.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherTaylor & Francises
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectCirugía refractivaes
dc.subjectCornea - Enfermedadeses
dc.titleMeasurement of correlation between transmission and scattering during wound healing in hen corneases
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1080/09500340902871389es
dc.identifier.publicationfirstpage1014es
dc.identifier.publicationissue8es
dc.identifier.publicationlastpage1021es
dc.identifier.publicationtitleJournal of Modern Opticses
dc.identifier.publicationvolume56es
dc.peerreviewedSIes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem