• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo UVaDOCComunidadesPor fecha de publicaciónAutoresMateriasTítulos

    Mi cuenta

    Acceder

    Estadísticas

    Ver Estadísticas de uso

    Compartir

    Ver ítem 
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Física Teórica, Atómica y Óptica
    • DEP33 - Artículos de revista
    • Ver ítem
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Física Teórica, Atómica y Óptica
    • DEP33 - Artículos de revista
    • Ver ítem
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/65294

    Título
    Intrasession repeatability and agreement of a new method to measure the foveal fixation axis
    Autor
    García Espinilla, ÓscarAutoridad UVA Orcid
    Sánchez Pavón, IreneAutoridad UVA Orcid
    Martín Herranz, RaúlAutoridad UVA Orcid
    Año del Documento
    2023
    Descripción
    Producción Científica
    Documento Fuente
    PeerJ, Febrero 2023, vol. 24, n. 11. p. e14942
    Resumen
    Purpose: Ophthalmic lens adaptation, particularly with progressive addition lenses, requires accurate measurements of the patient nasopupillary distance (NPD) and interpupillary distance (IPD), which are usually collected using the pupil centre as a reference. However, differences between the pupil centre and visual or foveal axis could induce some subsidiary effects of correcting lenses. This study aimed to assess the intrasession repeatability of a new prototype (Ergofocus®; Lentitech, Barakaldo, Spain) that can measure the foveal fixation axis (FFA) distance and assess the agreement with the NPD measurements collected using a traditional method (frame ruler). Methods: The FFA at far and near distances was measured three consecutive times in 39 healthy volunteers to determine the intrasession repeatability according to the British Standards Institute and International Organization for Standardization. Additionally, the FFA and NPD (standard frame ruler) were measured in 71 healthy volunteers and compared using Bland-Altman analysis. Two blinded experienced practitioners conducted each FFA and NPD measurement. Results: The FFA measurements showed acceptable repeatability at far distances (right eye (RE): Sw = 1.16 ± 0.76 mm and coefficient of variation (CV) = 3.92 ± 2.51%; left eye (LE) Sw = 1.11 ± 0.79 mm and CV = 3.76 ± 2.51%) and at near distances (RE: Sw = 0.97 ± 0.85 mm and CV = 3.52 ± 3.02%; LE: Sw = 1.17 ± 0.96 mm and CV = 4.54 ± 3.72%). Additionally, agreement with the NPD showed large differences at far distances (RE: -2.15 ± 2.34, LoA = -6.73 to 2.43 mm (P < 0.001); LE: -0.61 ± 2.62, LoA = -5.75 to 4.53 mm (P = 0.052)) and near distances (RE: -3.08 ± 2.80, LoA -8.57 to 2.42 mm (P < 0.001); LE: -2.97 ± 3.97, LoA: -10.75 to 4.80 mm (P < 0.001)). Conclusions: FFA measurements showed clinically acceptable repeatability at both far and near distances. Agreement with the NPD measured using a standard frame ruler showed significant differences, suggesting that both measurements are not interchangeable in clinical practice to prescribe and center ophthalmic lenses. Further research is necessary to assess the impact of FFA measurement in ophthalmic lens prescriptions.
    Materias (normalizadas)
    Optometría
    Palabras Clave
    Agreement
    Foveal fixation axis
    Intrasession repeatability
    Nasopupillary distance
    Ophthalmic lens prescription
    ISSN
    2167-8359
    Revisión por pares
    SI
    DOI
    10.7717/peerj.14942
    Idioma
    spa
    URI
    https://uvadoc.uva.es/handle/10324/65294
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Aparece en las colecciones
    • IOBA - Artículos de revista [80]
    • DEP33 - Artículos de revista [197]
    Mostrar el registro completo del ítem
    Ficheros en el ítem
    Nombre:
    peerj-14942.pdf
    Tamaño:
    2.147Mb
    Formato:
    Adobe PDF
    Descripción:
    Artículo principal
    Thumbnail
    Visualizar/Abrir
    Atribución 4.0 InternacionalLa licencia del ítem se describe como Atribución 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10