Mostrar el registro sencillo del ítem

dc.contributor.authorCoco Martín, Rosa María 
dc.contributor.authorAndrés Iglesias, Cristina
dc.contributor.authorSrivastava, Girish Kumar 
dc.contributor.authorLagos-Rodriguez, Javier
dc.contributor.authorRuiz-Tevah, Miguel
dc.contributor.authorDíaz-Cárdenas, Mario R.
dc.contributor.authorFernández Bueno, Iván 
dc.contributor.authorGarcía Serna, Juan 
dc.contributor.authorGarcía Gutiérrez, Maria Teresa
dc.contributor.authorGarcía-Layana, Alfredo
dc.contributor.authorPastor Jimeno, José Carlos 
dc.date.accessioned2024-07-22T09:34:46Z
dc.date.available2024-07-22T09:34:46Z
dc.date.issued2021-01-12
dc.identifier.citationSci Rep, Jan, 2021, vol. 11; n. 1, Nº artículo 599 (9 páginas).es
dc.identifier.issn2045-2322es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/68949
dc.descriptionProducción Científicaes
dc.description.abstractABSTRACT. Serious intraocular toxicity cases have been reported worldwide after the use of different perfluorocarbon liquids. The current study reports for the first-time the clinical pictures of cases of acute intraocular toxicity caused by Meroctane®, a perfluoro-octane commercialized by a Turkish company and distributed in many countries. A series of 18 cases from Chile and Spain was retrospectively analysed. To evaluate the impurity profile, a suspicious Meroctane® sample (lot OCT.01.2013) was analysed by gas chromatography mass spectrometry and compared with a non-suspicious sample of the same commercial perfluoro-octane (lot OCT 722011). Cytotoxicity was tested following a direct-contact method, taking into consideration the high volatility and hydrophobicity of perfluoro-octane and following the ISO 10993 guideline. Cytotoxicity test showed clear cytotoxic effects of the analysed batch (less than 9% of cell viability). Moreover, chemical analysis demonstrated the presence of many contaminants, some highly toxic (acids and alcohols). Perfluorocarbon liquids are useful tools for intraocular surgery but companies and Agencies of Medical Devices must implement measures that guarantee the safety of these products based on both chemical and cytotoxicity analysis for every batch. Medical staff should be encouraged to report any suspected case to their respective National Agencies.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherNature Publishing Groupes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.classificationTranslational research, Mass spectrometry, Cell culture, Retinaes
dc.titleIntraocular toxicity caused by MEROCTANE perfluorocarbon liquides
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1038/s41598-020-79561-yes
dc.relation.publisherversionhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7804266/es
dc.identifier.publicationfirstpage1es
dc.identifier.publicationissue1es
dc.identifier.publicationlastpage9es
dc.identifier.publicationtitleScientific Reportses
dc.identifier.publicationvolume11es
dc.peerreviewedSIes
dc.identifier.essn2045-2322es
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/submittedVersiones
dc.subject.unesco3201.09 Oftalmologíaes


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem