Mostrar el registro sencillo del ítem
dc.contributor.author | Valencia-Nieto, Laura | |
dc.contributor.author | López-de la Rosa, Alberto | |
dc.contributor.author | González García, María J. | |
dc.contributor.author | López-Miguel, Alberto | |
dc.date.accessioned | 2024-08-30T08:59:18Z | |
dc.date.available | 2024-08-30T08:59:18Z | |
dc.date.issued | 2024 | |
dc.identifier.citation | Ophthalmic and Physiological Optics, Enero 2024, vol. 44, n. 1. p. 124-130. | es |
dc.identifier.issn | 0275-5408 | es |
dc.identifier.uri | https://uvadoc.uva.es/handle/10324/69560 | |
dc.description | Producción Científica | es |
dc.description.abstract | Purpose: To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques. Methods: In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within-subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland–Altman method. Results: A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA-800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA-800 device provided significantly (p < 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups. Conclusion: Objective (CA-800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations. | es |
dc.format.mimetype | application/pdf | es |
dc.language.iso | eng | es |
dc.publisher | Wiley | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Lentes de contacto | es |
dc.subject.classification | Agreement | es |
dc.subject.classification | CA-800 | es |
dc.subject.classification | Contact lens | es |
dc.subject.classification | EasyTear® VIEW+ | es |
dc.subject.classification | Non-invasive break-up time | es |
dc.subject.classification | Repeatability | es |
dc.title | Reliability and agreement of subjective and objective non-invasive break-up time measurements in contact lens wearers | es |
dc.type | info:eu-repo/semantics/article | es |
dc.identifier.doi | https://doi.org/10.1111/opo.13243 | es |
dc.peerreviewed | SI | es |
dc.description.project | Ministry of Universities and European Social Fund, Grant/Award Number: FPU19/01109 | es |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | es |
dc.subject.unesco | 3201.09 Oftalmología | es |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
La licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional