Mostrar el registro sencillo del ítem

dc.contributor.authorOrtiz Toquero, Sara
dc.contributor.authorSánchez Pavón, Irene 
dc.contributor.authorGurrea, Carmen
dc.contributor.authorRecio Carnero, Alba
dc.contributor.authorBalsa, David
dc.contributor.authorMartín Herranz, Raúl 
dc.date.accessioned2024-09-25T11:15:27Z
dc.date.available2024-09-25T11:15:27Z
dc.date.issued2024
dc.identifier.citationLife, 2024, Vol. 14, Nº. 3, 407es
dc.identifier.issn2075-1729es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/70136
dc.descriptionProducción Científicaes
dc.description.abstractIn myopia control, it is essential to measure the axial length (AL) and corneal parameters, and to monitor whether changes in these parameters have occurred over time. The aim of this study was to analyse the repeatability and agreement between expert and non-expert practitioners in ocular parameters measured by the MYAH and Myopia Master. Three repeated measurements (n = 42) were recorded with the MYAH and Myopia Master by two (an expert and a non-expert) observers in a randomized order. The AL, K1, K2, and white-to-white (WTW) distance were collected. The intraobserver repeatability was excellent in all parameters measured with both devices in both observers. The AL outcome presented the best repeatability with the MYAH and Myopia Master (intraclass correlation coefficient, ICC = 1.0; coefficient of variation, CV ≤ 0.06% for both observers), while the WTW presented poorer results (ICC ≤ 0.991; CV ≤ 0.52%). The Myopia Master provides a significantly (p ≤ 0.01) flatter K1 and K2 as well as a lower WTW (p ≤ 0.01) than the MYAH. No statistically significant difference in AL measurements was found with either device (p ≥ 0.10; ICC = 1.0). None of the parameters showed differences (p ≥ 0.12) between the expert and non-expert observer. The MYAH and Myopia Master provide consistent measurements in a healthy adult population regardless of the previous clinical experience of the observer. AL measurements should be used interchangeably but K1, K2, and WTW should be used interchangeably with caution.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherMDPIes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectAxial lengthes
dc.subjectMyopiaes
dc.subjectMyopia controles
dc.subjectMiopíaes
dc.subjectPrecision medicinees
dc.subjectVision disorderses
dc.subjectVision, trastornos de laes
dc.subjectEye - Diseaseses
dc.subjectOjos - Enfermedadeses
dc.subjectMedicinees
dc.subjectOphthalmologyes
dc.subjectOptometry
dc.subjectPublic health
dc.titleThe repeatability and agreement of ocular parameters measured with the MYAH and Myopia Master devices between expert and non-expert practitionerses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2024 The authorses
dc.identifier.doi10.3390/life14030407es
dc.relation.publisherversionhttps://www.mdpi.com/2075-1729/14/3/407es
dc.identifier.publicationfirstpage407es
dc.identifier.publicationissue3es
dc.identifier.publicationtitleLifees
dc.identifier.publicationvolume14es
dc.peerreviewedSIes
dc.identifier.essn2075-1729es
dc.rightsAtribución 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones
dc.subject.unesco3201.09 Oftalmologíaes
dc.subject.unesco2209.15 Optometríaes
dc.subject.unesco32 Ciencias Médicases
dc.subject.unesco3212 Salud Publica


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem