Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/71491
Título
A discriminant analysis of the P3b wave with electroencephalogram by feature-electrode pairs in schizophrenia diagnosis
Año del Documento
2023
Editorial
John Wiley & Sons Ltd.
Descripción
Producción Científica
Documento Fuente
IET Signal Processing, e12230, vol. 17, Issue 6, 2023, pp. 1-20.
Résumé
Schizophrenia is a disease that affects approximately 1% of the population. Its early accurate diagnosis is of vital importance to apply adequate therapy as soon as possible. We present a Statistical Discriminant Diagnosing (SDD) system that discriminates between healthy controls and subjects and that supports diagnosis by a medical professional. The system works with {feature, electrode} EEG pairs which are selected based on the statistical significance of the p-values computed over the brain P3b wave. A bank of evoked potential pre-processed and filtered EEG signals is recorded during an auditory odd-ball (AOD) task and serves as input to the SDD system. These EEG signals comprise 20 features and 17 electrodes, both in time (t) and frequency (f) domain. The relevance of the Parieto-Temporal region is shown, allowing us to identify highly discriminant {feature, electrode} pairs in the detection of schizophrenia, resulting lower p-values in both Right and Left Hemispheres, as well as in Parieto-Temporal EEG signals. See for instance, the {PSE, P4} pair, with p-value = 0.00003 for (parametric) t Student and p-value = 0.00019 for (nonparametric) U Mann-Whitney tests, both under the 15 Hz cutoff frequency of a low pass EEG preprocessing filter. The relevance of this pair is in agreement with previously published related results. The proposed SDD system may provide the human expert (psychiatrist) with an objective complimentary information to help in the early diagnosis of schizophrenia.
Materias (normalizadas)
Detección
Esquizofrenia
Computer Aided Diagnosis
Onda P3b
Ayuda al diagnóstico
Ingeniería Biomédica
Procesado de señal
Materias Unesco
3306 Ingeniería y Tecnología Eléctricas
1209.04 Teoría y Proceso de decisión
Palabras Clave
Esquizofrenia
Diagnóstico
P3b
Sistema de Ayuda al Diagnóstico
Detección
Selección de características
ISSN
1751-9675
Revisión por pares
SI
Patrocinador
This work was supported by Instituto de Salud Carlos III under Fondo de Investigaciones Sanitarias (FIS) grant number FIS-PI11/02203, Spain.
Version del Editor
Idioma
eng
Tipo de versión
info:eu-repo/semantics/acceptedVersion
Derechos
openAccess
Aparece en las colecciones
Fichier(s) constituant ce document
Nombre:
Tamaño:
2.866Mo
Formato:
Adobe PDF
Descripción:
Artículo principal postprint aceptado
Excepté là où spécifié autrement, la license de ce document est décrite en tant que Attribution-NonCommercial-NoDerivatives 4.0 Internacional