Mostrar el registro sencillo del ítem

dc.contributor.authorArranz Gimón, Ángel Eugenio 
dc.contributor.authorZorita Lamadrid, Ángel Luis 
dc.contributor.authorMoríñigo Sotelo, Daniel 
dc.contributor.authorDuque Pérez, Óscar 
dc.date.accessioned2024-11-16T22:25:43Z
dc.date.available2024-11-16T22:25:43Z
dc.date.issued2021
dc.identifier.citationEnergies, 2021, vol. 14, n. 20, 6467es
dc.identifier.issn1996-1073es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/71540
dc.descriptionProducción Científicaes
dc.description.abstractHarmonic distortion is one of the disturbances that most affects the quality of the electrical system. The widespread use of power electronic systems, especially power converters, has increased harmonic and interharmonic emission in a wide range of frequencies. Therefore, there are new needs in the measurement of harmonic distortion in modern electrical systems, such as measurement in the supra-harmonic range (>2 kHz) and the measurement of interharmonics. The International Electrotechnical Commission (IEC) standards define new total harmonic distortion (THD) rates based on the concept of frequency groupings. However, the rates defined in the IEC standards have shortcomings when measuring signals such as those present in the outputs of power systems with abundant interharmonic content and presence of components in the supra-harmonic range. Therefore, in this work, a comparison is made between the different THD factors currently defined, both in the literature and in the standards, to show which of them are the most suitable for assessing harmonic and interharmonic contamination in power system signals such as those present at the output of inverters.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherMDPIes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.classificationHarmonic distortion rateses
dc.subject.classificationTasas de Distorsión armónicaes
dc.subject.classificationElectric poweres
dc.subject.classificationEnergía eléctricaes
dc.subject.classificationHigh-frequency interharmonicses
dc.subject.classificationInterarmónicos de altas frecuenciases
dc.titleA Review of Total Harmonic Distortion Factors for the Measurement of Harmonic and Interharmonic Pollution in Modern Power Systemses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2021 The Authorses
dc.identifier.doi10.3390/en14206467es
dc.relation.publisherversionhttps://www.mdpi.com/1996-1073/14/20/6467es
dc.identifier.publicationfirstpage6467es
dc.identifier.publicationissue20es
dc.identifier.publicationtitleEnergieses
dc.identifier.publicationvolume14es
dc.peerreviewedSIes
dc.identifier.essn1996-1073es
dc.rightsAtribución 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones
dc.subject.unesco3306 Ingeniería y Tecnología Eléctricases


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem