• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo UVaDOCComunidadesPor fecha de publicaciónAutoresMateriasTítulos

    Mi cuenta

    Acceder

    Estadísticas

    Ver Estadísticas de uso

    Compartir

    Ver ítem 
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia
    • DEP11 - Artículos de revista
    • Ver ítem
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia
    • DEP11 - Artículos de revista
    • Ver ítem
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/74388

    Título
    Influence of decentration and tilt of Tecnis ZCB00 on visual acuity and higher order aberrations
    Autor
    Martínez Plaza, ElenaAutoridad UVA
    López De La Rosa, AlbertoAutoridad UVA Orcid
    Papadatou, Eleni
    Habib, Nabil E.
    Águila Carrasco, Antonio J. del
    López Miguel, AlbertoAutoridad UVA Orcid
    Maldonado López, Miguel JoséAutoridad UVA Orcid
    Buckhurst, Phillip J.
    Año del Documento
    2023-06
    Editorial
    Springer Nature
    Descripción
    Producción Científica
    Documento Fuente
    Martínez-Plaza E, López-de la Rosa A, Papadatou E, Habib NE, Del Águila-Carrasco AJ, López-Miguel A, Maldonado MJ, Buckhurst PJ. Influence of decentration and tilt of Tecnis ZCB00 on visual acuity and higher order aberrations. Eye (Lond). 2023 Jun;37(8):1640-1645
    Resumen
    Background/objectives: To determine the influence of decentration and tilt of a pseudophakic aspheric intraocular lens (IOL) on visual acuity (VA) and higher-order aberrations (HOAs), and to analyze the agreement between pupil center/axis and iridocorneal angles center/axis when assessing IOL decentration and tilt. Subjects/methods: A prospective interventional case series study including thirty-three patients undergoing Tecnis ZCB00 (Abbott Medical Optics) implantation. IOL decentration and tilt with respect to two reference systems (pupil and iridocorneal angles centers/axes), in cartesian (X,Y) and polar (radius/tilt, polar angle/azimuth) coordinates, were assessed with optical coherence tomography. VA and internal and ocular HOAs were evaluated. Multiple linear regression models and intraclass correlation coefficient (ICC) were computed. Results: IOL decentration only showed a significant effect on internal HOAs for [Formula: see text] (R2 = 0.20, P = 0.04). IOL decentration with respect to the pupil center showed a significant effect on ocular [Formula: see text] (R2 = 0.18, P = 0.05), [Formula: see text] (R2 = 0.36, P = 0.001) and [Formula: see text] (R2 = 0.24, P = 0.02); and with respect to the center of iridocorneal angles, on ocular [Formula: see text] (R2 = 0.21, P = 0.03), [Formula: see text] (R2 = 0.32, P = 0.003), primary coma (R2 = 0.41, P < 0.001), and coma-like (R2 = 0.40, P = 0.001). Poor agreement between both reference systems was found for IOL decentration measurements (ICC ≤ 0.41), except for the polar angle coordinate (ICC = 0.83). Tilt measurements showed good agreement (ICC ≥ 0.75). Conclusions: Tecnis ZCB00 decentration and tilt values after uneventful implantation appear not to have influence on VA, and their effect on HOAs are not high enough to clinically affect quality of vision. Pupil and iridocorneal angles used as reference systems may be interchangeable for IOL tilt measurements, but not for decentration.
    ISSN
    0950-222X
    Revisión por pares
    SI
    DOI
    10.1038/s41433-022-02211-2
    Patrocinador
    Junta de Castilla y León and European Social Fund (EDU/ 1100/2017).
    Version del Editor
    https://www.nature.com/articles/s41433-022-02211-2
    Propietario de los Derechos
    The Author(s), under exclusive licence to The Royal College of Ophthalmologists 2022
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/74388
    Tipo de versión
    info:eu-repo/semantics/submittedVersion
    Derechos
    restrictedAccess