Mostrar el registro sencillo del ítem
dc.contributor.author | Martínez Plaza, Elena | |
dc.contributor.author | Barberan Bernardos, Laura | |
dc.contributor.author | Molina Martín, Ainhoa | |
dc.contributor.author | Piñero Llorens, David | |
dc.contributor.editor | Antonio Ferreras | es |
dc.date.accessioned | 2025-02-27T12:04:50Z | |
dc.date.available | 2025-02-27T12:04:50Z | |
dc.date.issued | 2024-10-12 | |
dc.identifier.citation | Martínez-Plaza, E.; Barberán-Bernardos, L.; Molina-Martín, A.; Piñero, D.P. Diagnostic Performance of Visionix VX120+ Platform for Dry Eye Screening. Diagnostics 2024, 14, 2276. | es |
dc.identifier.uri | https://uvadoc.uva.es/handle/10324/75172 | |
dc.description.abstract | Objective: To evaluate the accuracy of diagnosing dry eye disease (DED) by using the Visionix VX120+, to establish reference values for tear meniscus height (TMH) and non-invasive break-up time (NIBUT), and to compare the NIBUT measurements with the fluorescein tear break-up time (FBUT), Methods: fifty-eight subjects (34 dry eye and 24 control) were enrolled. The TMH, first NIBUT, and NIBUT50% were evaluated with the Visionix VX120+, and the FBUT was measured with a slit-lamp. The Receiver Operating Characteristic (ROC) curve was used to evaluate the diagnostic performance, and the Bland–Altman method was performed to analyze the agreement. Results: The areas under the curve were 0.62, 0.60, and 0.70 for the TMH, first NIBUT, and NIBUT50%, respectively. The optimal cut-off values (sensitivity, specificity) were 0.29 (0.62, 0.67), 5.05 (0.85, 0.46), and 7.35 (0.65, 0.79) for the TMH, first NIBUT, and NIBUT50%, respectively. The mean differences (lower, upper limits of agreement) were −1.10 (−8.78, 6.58) and 1.55 (−5.68, 8.78) for the first NIBUT vs. FBUT and the NIBUT50% vs. FBUT, respectively. Conclusions: In conclusion, the NIBUT50% can be a useful tool for dry eye screening, with acceptable values of sensitivity and specificity. First, the NIBUT and NIBUT50% should not be used interchangeably with the FBUT. | es |
dc.format.mimetype | application/pdf | es |
dc.language.iso | eng | es |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es |
dc.subject.classification | tear meniscus height; TMH; tear break-up time; NIBUT; accuracy; Visionix; dry eye; screening | es |
dc.title | Diagnostic Performance of Visionix VX120+ Platform for Dry Eye Screening | es |
dc.type | dataset | es |
dc.identifier.doi | 10.35376/10324/75172 | |
dc.type.hasVersion | info:eu-repo/semantics/draft | es |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
- Datasets [61]