Afficher la notice abrégée

dc.contributor.advisorMateos Villán, David es
dc.contributor.advisorHerrero Anta, Sara es
dc.contributor.authorDíaz de Pablos, Paula
dc.contributor.editorUniversidad de Valladolid. Facultad de Ciencias es
dc.date.accessioned2025-09-19T14:11:40Z
dc.date.available2025-09-19T14:11:40Z
dc.date.issued2025
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/77953
dc.description.abstractEste trabajo de fin de grado presenta un estudio sobre la transmitancia de cuatro lentes oftálmicas blancas, evaluadas en el rango espectral comprendido entre 300 nm y 1000 nm, con especial atención a su comportamiento frente a la luz azul. De esta forma, se ha podido comparar la información que aporta cada fabricante con datos experimentales y estudiar su eficacia de protección frente a los dispositivos electrónicos actuales. Las medidas se han obtenido utilizando un espectroradiómetro LI-COR 1800 manejado con el programa informático WIN-1800. Se analizan las transmitancias espectrales de las cuatro lentes, observándose que, a partir de los 420-450 nm, la mayoría presentan transmitancias superiores al 80%. En la discusión se detallan las características de los filtros de absorción de los diferentes productos ofrecidos por las casas comerciales para la longitud de onda entorno 300-500nm. Tras el análisis, se ha observado que, de manera general, estos tratamientos son más eficaces en el rango ultravioleta, por debajo de los 400 nm, mientras que permiten una alta transmitancia en el rango de 420-450 nm coincidente con la emisión principal de las pantallas actuales, con valores superiores al 85–90%.es
dc.description.abstractThis undergraduate thesis presents a study on the transmittance of four clear ophthalmic lenses, evaluated within the spectral range of 300 nm to 1000 nm, with particular focus on their behaviour in response to blue light. This way, it has been possible to compare the information provided by each manufacturer with experimental data and assess their effectiveness in protecting against current electronic devices. Measurements were obtained using a LI-COR 1800 spectroradiometer operated with the WIN-1800 software. The spectral transmittances of the four lenses are analysed, revealing that, from 420–450 nm onwards, most show transmittance values above 80%. The discussion section details the absorption filter characteristics of the various products offered by commercial brands within the 300–500 nm wavelength range. Following the analysis, it was observed that these treatments are generally more effective in the ultraviolet range below 400 nm, while allowing high transmittance in the 420- 450 nm range, which coincides with the main emission band of modern screens, with values exceeding 85-90%.es
dc.description.sponsorshipDepartamento de Física Teórica, Atómica y Ópticaes
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.classificationLuz azules
dc.subject.classificationFiltroses
dc.subject.classificationTransmitanciaes
dc.titleTratamientos aplicados en lentes oftálmicas para bloquear la luz azul Ies
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.description.degreeGrado en Óptica y Optometríaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée