Show simple item record

dc.contributor.authorRodríguez Esteban, María Ascensión
dc.contributor.authorCamino Olea, María Soledad 
dc.contributor.authorSáez Pérez, María Paz
dc.contributor.authorRamón Cueto, Gemma 
dc.contributor.authorBellido Pla, Rosa Luz 
dc.date.accessioned2025-10-16T10:19:37Z
dc.date.available2025-10-16T10:19:37Z
dc.date.issued2025
dc.identifier.citationMEMORIAS CONPAT2025 XVIII Congreso Iberoamericano de Patología de la Construcción XX Congreso de Control de Calidad en la Construcción, 2025, p. 616-627-es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/78726
dc.descriptionProducción Científicaes
dc.description.abstractThe assessment of the risk of surface condensation on the walls of Cultural Heritage buildings is crucial, since it has been identified that the analytical method used for new buildings can generate errors in these properties. The objective of this research is therefore focused on comparing the differences in surface temperatures between those calculated by the analytical method and those obtained by the in situ measurement. For its determination, the ambient and surface temperatures of the facade of a historic building have been measured, and heat flow tests have been carried out to estimate the conductivity of the walls. By contrasting the results obtained with the data calculated from the analytical system, it is concluded that this method is not entirely valid for this type of building.es
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.publisherÁngel Castillo Talavera, José Luis García Calvo, Enio J. Pazini Figueiredo y Pedro Castro Borgeses
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectConstrucción, Ladrillo, Condensación superficial, Patrimonio histórico, Flujo térmicoes
dc.subject.classificationbrick; cultural heritage; surface condensation; moisture; thermal flow testes
dc.titleAssessment of the risk of surface condensation on cultural heritage mechanical brick facades: the importance of surface temperature measurement. The case of a historic building in Valladolid.es
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.21041/CONPAT2025/V2PC23es
dc.identifier.publicationfirstpage616es
dc.identifier.publicationlastpage627es
dc.peerreviewedSIes
dc.description.projectproyecto de investigación “PID2022-139363NB-I00”, financiado por MICIU/AEI/10.13039/501100011033 y por FEDER, UE.es
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones
dc.subject.unesco3305.01 Diseño Arquitectónicoes
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record