Zur Kurzanzeige

dc.contributor.authorGuantay, Carla
dc.contributor.authorMena-García, Laura
dc.contributor.authorTola-Arribas, Miguel
dc.contributor.authorGarea García-Malvar, María José
dc.contributor.authorYugueros Fernández, María
dc.contributor.authorMayo-Iscar, Agustín
dc.contributor.authorPastor, José
dc.date.accessioned2026-01-25T12:04:14Z
dc.date.available2026-01-25T12:04:14Z
dc.date.issued2024
dc.identifier.citationCarla D Guantay, Laura Mena-García, Miguel Ángel Tola-Arribas, María José Garea García-Malvar, María Isabel Yugueros Fernández, Agustín Mayo-Iscar & José Carlos Pastor (2024) Correlations Between Disability Score, Optical Coherence Tomography and Microperimetry in Patients with Multiple Sclerosis, Eye and Brain, , 89-100, DOI: 10.2147/ EB.S469182es
dc.identifier.issn11792744es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/82133
dc.descriptionProducción Científicaes
dc.description.abstractPurpose: To characterize ocular motility disturbances through Microperimetry (MP) in patients with Multiple Sclerosis (MS) trying to detect those capable of influencing the disability to improve the accuracy of assessing visual impact in EDSS scale. MP results were compare with some structural parameters obtained by OCT. Patients and methods: Cross-sectional analytical and correlational case-control study approved by Ethical Committee. A total of 82 eyes (41 patients) and 30 healthy eyes (15 subjects) were enrolled after informed consent. All participants underwent ophthalmological evaluation with MP and OCT. Variables included MS disease duration, Expanded Disability Status Scale (EDSS) score; in OCT: central macular thickness (CMT), ganglion cell-inner plexiform layer thickness (GCIPL), and peripapillary retinal nerve fiber layer thickness (pRNFL); and in MP: test duration, reaction time, average macular threshold (AT), and 4 fixation stability indexes (P1, P2, BCEA63, BCEA95). Results: MS group showed a significant decrease in GCIPL (p < 0.001) and pRNFL thickness (p < 0.001) compared to the control group. Furthermore, patients demonstrated a longer examination (p < 0.001) and reaction (p < 0.001) times, reduced AT (p < 0.001), more unstable fixation indexes (P1 p <0.004, P2 p = 0.018, BCEA63 p = 0.005 and BCEA95 p = 0.007), measured by MP. In addition, patients with a history of ON (n=16) demonstrated longer examination times in MP (p = 0.049) compared to MS patients without ON, but they were not correlations with OCT measurements, EDSS score correlated with the CMT (p = 0.023, r = -0.25), MP duration (p = 0.043, r = 0.22), and fixation indexes (P1 p = 0.049, r = -0.22, BCEA63 p = 0.041, r = 0.23, BCEA95 p = 0.049, r = 0.22). Conclusion: Our study emphasizes the complementary utility of MP and OCT in assessing MS patients. Additionally, it highlights that using MP for objective measurements of oculomotor dysfunction could improves accuracy in disability assessment on the EDSS scale.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherDovePress. Taylor & Francises
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/*
dc.subject.classificationocular movement anomalies, expanded disability status scale, neurodegenerative diseases, fixation instability, retinal sensitivityes
dc.titleCorrelations Between Disability Score, Optical Coherence Tomography and Microperimetry in Patients with Multiple Sclerosises
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.2147/EB.S469182es
dc.relation.publisherversionhttps://www.tandfonline.com/doi/metrics/10.2147/EB.S469182?scroll=top#metrics-summaryes
dc.identifier.publicationfirstpage89es
dc.identifier.publicationlastpage100es
dc.identifier.publicationtitleEye and Braines
dc.identifier.publicationvolumeVolume 16es
dc.peerreviewedSIes
dc.description.projectThis study was supported by the grants from the Gerencia Regional de Salud de Castilla y León (grant no. GRS 2498/A/ 22). Agustín Mayo-Iscar research was partially supported by grant PID2021-128314NB-I00 funded by MCIN/AEI/ 10.13039/501100011033/FEDER.es
dc.identifier.essn1179-2744es
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Unported*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige