• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Ricerca

    Tutto UVaDOCArchiviData di pubblicazioneAutoriSoggettiTitoli

    My Account

    Login

    Estadísticas

    Ver Estadísticas de uso

    Compartir

    Mostra Item 
    •   UVaDOC Home
    • PRODUZIONE SCIENTIFICA
    • Departamentos
    • Dpto. Ingeniería Eléctrica
    • DEP45 - Artículos de revista
    • Mostra Item
    •   UVaDOC Home
    • PRODUZIONE SCIENTIFICA
    • Departamentos
    • Dpto. Ingeniería Eléctrica
    • DEP45 - Artículos de revista
    • Mostra Item
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/83242

    Título
    Non-Uniform Time Resampling for Diagnosing Broken Rotor Bars in Inverter-Fed Induction Motors
    Autor
    García Calva, Tomás AlbertoAutoridad UVA
    Romero Troncoso, René de Jesús
    Moríñigo Sotelo, DanielAutoridad UVA Orcid
    Año del Documento
    2017
    Editorial
    Institute of Electrical and Electronics Engineers
    Documento Fuente
    T. A. Garcia-Calva, D. Morinigo-Sotelo and R. de Jesus Romero-Troncoso, "Non-Uniform Time Resampling for Diagnosing Broken Rotor Bars in Inverter-Fed Induction Motors," in IEEE Transactions on Industrial Electronics, vol. 64, no. 3, pp. 2306-2315, March 2017
    Abstract
    Fault detection in inverter-fed induction motors (IMs) is an actual industrial need. Many line-fed machines are being replaced by inverter-fed drives for improving control during startup and also for saving energy. Broken rotor bars (BRBs) in IMs is one of the most difficult faults to be detected, particularly when the motor is fed by an inverter in a soft startup. The difficulty of detecting BRBs is that the characteristic fault-related frequencies are very close to the fundamental frequency, and the amplitude of the fundamental is significantly higher than the fault-related frequency components. This paper proposes an effective method that allows the detection of the BRB fault in inverter-fed IMs during a soft startup transient based on a non-uniform resampling algorithm. The proposed algorithm transforms the nonstationary fundamental frequency into a stationary component by non-uniform resampling, whereas the fault-related components are considerably separated from the fundamental one, making easier to follow their evolution during the startup transient. Simulation and experimental results demonstrate the effectiveness of the proposed method to detect the fault.
    ISSN
    0278-0046
    Revisión por pares
    SI
    DOI
    10.1109/TIE.2016.2619318
    Version del Editor
    https://ieeexplore.ieee.org/document/7604109
    Propietario de los Derechos
    IEEE
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/83242
    Tipo de versión
    info:eu-repo/semantics/draft
    Derechos
    restrictedAccess
    Aparece en las colecciones
    • DEP45 - Artículos de revista [52]