Afficher la notice abrégée

dc.contributor.authorTanis-Kanbur, Melike Begum
dc.contributor.authorPeinador, René
dc.contributor.authorHu, Xiao
dc.contributor.authorCalvo Díez, José Ignacio 
dc.contributor.authorChew, Jia Wei
dc.date.accessioned2026-03-25T08:49:30Z
dc.date.available2026-03-25T08:49:30Z
dc.date.issued2019
dc.identifier.citationJournal of Membrane Science, September 2019, 586, 248-258es
dc.identifier.issn0376-7388es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/83807
dc.descriptionProducción Científicaes
dc.description.abstractTo comparatively assess the Evapoporometry (EP) technique vis-à-vis the Liquid-Liquid Displacement Porosimetry (LLDP) technique, the pore size distributions, mean pore diameters (davg) and porosities of five polymeric (namely, nylon, PES, PTFE, PET and PVDF) and one inorganic (namely, alumina) UF/tight MF membranes were quantified by both techniques. For all the membranes, the pore size ranges were generally narrower and the pore size distributions had distinctive peaks for the LLDP technique. For the nylon, PES and PTFE membranes, the davg values obtained from the two techniques agreed well. However, for the PET and PVDF membranes, the differences were twofold due to the higher pressure needed for the LLDP tests. Specifically, for PET, the davg value obtained via EP was half that via LLDP, because the higher pressure compacted the lower mechanical strength polymer, leading to pore closure. On the other hand, for PVDF, due to the rubber nature, the higher pressure caused the pores to be stretched, leading to larger pores. As for the alumina membrane, because of the more ideal cylindrical pores, the d4-weighting of the LLDP measurement gave a greater davg value than that of the d2-weighting of the EP measurement. Also, porosity measurements were erroneous for LLDP if the active layer cannot be precisely quantified. With respect to MWCO, while EP does not explicitly quantify this, the LLDP generally over-estimated the values, because of the errors associated with the measurement of the first (largest) pores at the lowest pressures.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherElsevieres
dc.rights.accessRightsinfo:eu-repo/semantics/embargoedAccesses
dc.subject.classificationDistribución del tamaño de poro (PSD)es
dc.subject.classificationHumectabilidad
dc.subject.classificationTensión superficial
dc.subject.classificationCaracterización de membranas
dc.subject.classificationPorosidad
dc.titleMembrane characterization via evapoporometry (EP) and liquid-liquid displacement porosimetry (LLDP) techniqueses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2019 Elsevier B.Ves
dc.identifier.doi10.1016/j.memsci.2019.05.077es
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S0376738819311743?via%3Dihub
dc.identifier.publicationfirstpage248es
dc.identifier.publicationlastpage258es
dc.identifier.publicationtitleJournal of Membrane Sciencees
dc.identifier.publicationvolume586es
dc.peerreviewedSIes
dc.description.projectRegional Government of Castilla y León (Projects: CLU2017-09, UIC082 and VA088G19) and the Spanish “Ministerio de Ciencia e Innovación (MCINN)” (project: MAT2016-76413-C2-1-R)es
dc.type.hasVersioninfo:eu-repo/semantics/draftes


Fichier(s) constituant ce document

Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée