<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T13:22:07Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/33058" metadataPrefix="dim">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/33058</identifier><datestamp>2021-06-24T07:41:42Z</datestamp><setSpec>com_10324_33219</setSpec><setSpec>com_10324_954</setSpec><setSpec>com_10324_894</setSpec><setSpec>com_10324_966</setSpec><setSpec>com_10324_952</setSpec><setSpec>com_10324_1170</setSpec><setSpec>com_10324_931</setSpec><setSpec>col_10324_33220</setSpec><setSpec>col_10324_967</setSpec><setSpec>col_10324_1367</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="cbdaa7ca6b483c8f" confidence="500" orcid_id="0000-0003-0491-4371">Villafruela Espina, José Manuel</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="3ac3687098f25b5f" confidence="500" orcid_id="">San José Alonso, Julio Francisco</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="0810642d19e318d9" confidence="500" orcid_id="0000-0002-7038-7517">Castro Ruiz, Francisco</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="18a646c4-aa8b-4775-99de-62e4dd8b81a2" confidence="500" orcid_id="">Zarzuelo Sánchez, Andrés Manuel</dim:field>
<dim:field mdschema="dc" element="date" qualifier="accessioned">2018-11-29T11:34:51Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="available">2018-11-29T11:34:51Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="issued">2016</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="citation" lang="es">Building and Environment, 2016, Volume 109, Pages 190-198</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="issn" lang="es">03601323</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="uri">http://uvadoc.uva.es/handle/10324/33058</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="doi" lang="es">10.1016/j.buildenv.2016.09.025</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationfirstpage" lang="es">190</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationissue" lang="es">109</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationlastpage" lang="es">198</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationtitle" lang="es">Building and Environment</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationvolume" lang="es">109</dim:field>
<dim:field mdschema="dc" element="description" lang="es">Producción Científica</dim:field>
<dim:field mdschema="dc" element="description" qualifier="abstract" lang="es">It is common practice for operating rooms (OR) to have more pressure than the adjacent enclosures. This is to prevent the entry of potentially contaminated air and the consequent risk of wound infection. However, when the OR door is opened the pressure difference between the two areas disappears and can cause containment failures. If a person enters or leaves the OR during door operation, additional perturbations are also generated in the airflow pattern in the doorway. In this paper, instantaneous airflows are measured during the passage of a person through a sliding door in a real OR with the HVAC system working under operating conditions. An ultrasonic anemometer that measures the magnitude and direction of the instantaneous air velocity in the doorway is used. Results show that, even though the OR has a sliding door and an initial overpressure of 20 Pa, together with what is, a priori, a good HVAC system control strategy, a small volume of air enters the OR during a cycle of door opening and closing even without the passage of a person. Furthermore, if a person walks through the door the volume of air entering the OR is higher, especially if the person enters the OR. © 2016 Elsevier Ltd</dim:field>
<dim:field mdschema="dc" element="description" qualifier="project" lang="es">Ministry of Economy and Competiveness  project DPI2014-55357-C2-1-R  cofinanced by the European Regional Development Fund (ERDF).</dim:field>
<dim:field mdschema="dc" element="format" qualifier="mimetype" lang="es">application/pdf</dim:field>
<dim:field mdschema="dc" element="language" qualifier="iso" lang="es">eng</dim:field>
<dim:field mdschema="dc" element="publisher" lang="es">Elsevier</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="accessRights" lang="es">info:eu-repo/semantics/restrictedAccess</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="holder" lang="es">Elsevier Ltd</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Ventilation</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Indoor air pollution</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Airborne infectious</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Operating room</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Door opening</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Sliding door</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Ultrasonic anemometry</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Foot traffic</dim:field>
<dim:field mdschema="dc" element="title" lang="es">Airflow patterns through a sliding door during opening and foot traffic in operating rooms</dim:field>
<dim:field mdschema="dc" element="type" lang="es">info:eu-repo/semantics/article</dim:field>
<dim:field mdschema="dc" element="relation" qualifier="publisherversion" lang="es">https://www.sciencedirect.com/science/article/pii/S0360132316303729</dim:field>
<dim:field mdschema="dc" element="peerreviewed" lang="es">SI</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>