<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T22:08:33Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/33204" metadataPrefix="marc">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/33204</identifier><datestamp>2021-07-06T08:34:04Z</datestamp><setSpec>com_10324_1170</setSpec><setSpec>com_10324_931</setSpec><setSpec>com_10324_894</setSpec><setSpec>com_10324_33219</setSpec><setSpec>com_10324_954</setSpec><setSpec>com_10324_966</setSpec><setSpec>com_10324_952</setSpec><setSpec>col_10324_1367</setSpec><setSpec>col_10324_33220</setSpec><setSpec>col_10324_967</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Berlanga Cañete, Félix Antonio</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Olmedo Cortés, Inés</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Ruiz de Adana, Manuel</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Villafruela Espina, José Manuel</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">San José Alonso, Julio Francisco</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Castro Ruiz, Francisco</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2018</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">This study evaluates the convenience of the use of four different mixing ventilation configurations in individual hospital rooms (IHR) based on ventilation performance and health workers (HW) exposure to the contaminants released by a confined patient (CP). Two supply configurations: grilles in the upper part of a wall (G) and swirl ceiling diffusers (S), combined with two different exhaust grilles positions in the opposite wall: upper part (U) and lower part (D) are tested using typical IHR set up. Occupants are represented by thermal breathing manikins, CP lies on a bed while HW stands close to it. Three air renewal rates are tested to determine their influence in the studied variables, 6, 9 and 12 ACH covering the whole range of ventilation requirements of such spaces. The experimental conditions considering the thermal comfort of the occupants are taken into account. Different ventilation configurations create different air distribution patterns inside the room. G configurations lead to high HW transient exposure values while S maintain low values that decrease when ACH is increased, so this second configuration is preferred for IHRs. Results are also compared with a displacement ventilation (DV) study highlighting the convenience of this strategy for IHRs. © 2018 Elsevier B.V.</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">Energy and Buildings, 2018, Volume 177, 15, Pages 207-219</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">03787788</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">http://uvadoc.uva.es/handle/10324/33204</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">10.1016/j.enbuild.2018.07.053</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">207</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">219</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">Energy and Buildings</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">177</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Ventilation</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Indoor air pollution</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Airborne infectious</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Experimental assessment of different mixing air ventilation systems on ventilation performance and exposure to exhaled contaminants in hospital rooms</subfield>
</datafield>
</record></metadata></record></GetRecord></OAI-PMH>