<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T19:55:34Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/41052" metadataPrefix="marc">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/41052</identifier><datestamp>2021-06-23T11:22:49Z</datestamp><setSpec>com_10324_1170</setSpec><setSpec>com_10324_931</setSpec><setSpec>com_10324_894</setSpec><setSpec>col_10324_1367</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<leader>00925njm 22002777a 4500</leader>
<datafield tag="042" ind1=" " ind2=" ">
<subfield code="a">dc</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Velasco Gómez, Eloy</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Tejero González, Ana</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="720" ind1=" " ind2=" ">
<subfield code="a">Rey Martínez, Francisco Javier</subfield>
<subfield code="e">author</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2012</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The present paper aims to describe the experimental study developed to characterize an indirect evaporative cooling system made of polycarbonate, designed and manufactured by the Thermal Engineering Group of the University of Valladolid; as well as to introduce the main results obtained.&#xd;
The prototype is characterized by a total heat exchange area of 6 m2 and is installed in a heat recovery cycle in the experimental setup constructed in the laboratory. This setup mainly consists of: an AHU that enables the reproduction of the different climatic conditions to be tested; a climatic chamber where comfort conditions are to be achieved; a circuit to supply water during one of the operating modes; and the due ducts and measurement probes to properly connect the whole system and register the evolution of the interesting parameters.&#xd;
Two operating modes are performed. In the first one, exhaust air from the climate chamber, in comfort conditions, goes through one side of the heat exchanger, producing heat transfer from the outdoor air stream through the plastic walls of the system. In the second case, an evaporative cooling mode is implemented by supplying water to the exhaust airstream.&#xd;
Results obtained show that heat transfer through the heat exchanger polycarbonate wall improves in the evaporative cooling mode. Furthermore, both cooling capacity and thermal effectiveness of the system also increase in the second case. Moreover, global heat transfer coefficient and cooling capacity are improved by higher outdoor air volume flow rates. Finally, higher outdoor air temperatures imply better cooling capacities and thermal effectiveness.</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">Applied Energy, September 2012, vol 97, p.: 340-346</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">0306-2619</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">http://uvadoc.uva.es/handle/10324/41052</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">10.1016/j.apenergy.2011.12.065</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">340</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">346</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">Applied Energy</subfield>
</datafield>
<datafield tag="024" ind2=" " ind1="8">
<subfield code="a">97</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Eficiencia energética</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Climatización</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Edificios</subfield>
</datafield>
<datafield ind1=" " ind2=" " tag="653">
<subfield code="a">Enfriamiento evaporativo</subfield>
</datafield>
<datafield tag="245" ind1="0" ind2="0">
<subfield code="a">Experimental characterisation of an indirect evaporative cooling prototype in two operating modes</subfield>
</datafield>
</record></metadata></record></GetRecord></OAI-PMH>