<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-27T21:22:21Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/41997" metadataPrefix="edm">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/41997</identifier><datestamp>2025-02-20T08:31:40Z</datestamp><setSpec>com_10324_1170</setSpec><setSpec>com_10324_931</setSpec><setSpec>com_10324_894</setSpec><setSpec>col_10324_1367</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xsi:schemaLocation="http://www.w3.org/1999/02/22-rdf-syntax-ns# http://www.europeana.eu/schemas/edm/EDM.xsd">
<edm:ProvidedCHO rdf:about="http://uvadoc.uva.es/handle/10324/41997">
<dc:creator>Andrés Chicote, Manuel</dc:creator>
<dc:creator>Tejero González, Ana</dc:creator>
<dc:creator>Velasco Gómez, Eloy</dc:creator>
<dc:creator>Rey Martínez, Francisco Javier</dc:creator>
<dc:date>2012</dc:date>
<dc:description>Nowadays, radiant ceiling systems can be considered among the technologies capable of meeting sustainable heating and cooling requirements. In order to adequately address design and simulation issues concerning these systems, correct evaluation of the heat transfer process is needed.&#xd;
The aim of this research is to present further evidence on the cooling capacity and heat transfer coefficients for a cooled radiant ceiling, assuring adequate thermal comfort levels in those possible different operation conditions. An experimental setup into a climate test room was developed and used to derive convenient results.&#xd;
The obtained values revealed that heat transfer evaluations on the basis of operative temperature as the unique reference temperature and corresponding total coefficient are not appropriate in real situations, but considering radiant and convective phenomena separately is strongly recommended.</dc:description>
<dc:format>application/pdf</dc:format>
<dc:identifier>http://uvadoc.uva.es/handle/10324/41997</dc:identifier>
<dc:language>spa</dc:language>
<dc:publisher>Elsevier</dc:publisher>
<dc:subject>Eficiencia energética</dc:subject>
<dc:subject>Climatización</dc:subject>
<dc:subject>Edificios</dc:subject>
<dc:subject>3322</dc:subject>
<dc:title>Experimental study on the cooling capacity of a radiant cooled ceiling system</dc:title>
<dc:type>info:eu-repo/semantics/article</dc:type>
<edm:type>TEXT</edm:type>
</edm:ProvidedCHO>
<ore:Aggregation rdf:about="http://uvadoc.uva.es/handle/10324/41997#aggregation">
<edm:aggregatedCHO rdf:resource="http://uvadoc.uva.es/handle/10324/41997"/>
<edm:dataProvider>UVaDOC. Repositorio Documental de la Universidad de Valladolid</edm:dataProvider>
<edm:isShownAt rdf:resource="http://uvadoc.uva.es/handle/10324/41997"/>
<edm:isShownBy rdf:resource="https://uvadoc.uva.es/bitstream/10324/41997/1/AcceptedManuscript_E%26B2012.pdf"/>
<edm:provider>Hispana</edm:provider>
<edm:rights rdf:resource="http://rightsstatements.org/vocab/CNE/1.0/"/>
</ore:Aggregation>
<edm:WebResource rdf:about="https://uvadoc.uva.es/bitstream/10324/41997/1/AcceptedManuscript_E%26B2012.pdf">
<edm:rights rdf:resource="http://rightsstatements.org/vocab/CNE/1.0/"/>
</edm:WebResource>
</rdf:RDF></metadata></record></GetRecord></OAI-PMH>