<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-23T20:28:03Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/44978" metadataPrefix="edm">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/44978</identifier><datestamp>2023-01-01T22:16:01Z</datestamp><setSpec>com_10324_38</setSpec><setSpec>col_10324_852</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ore="http://www.openarchives.org/ore/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:edm="http://www.europeana.eu/schemas/edm/" xsi:schemaLocation="http://www.w3.org/1999/02/22-rdf-syntax-ns# http://www.europeana.eu/schemas/edm/EDM.xsd">
<edm:ProvidedCHO rdf:about="http://uvadoc.uva.es/handle/10324/44978">
<dc:contributor>Sánchez Pavón, Irene</dc:contributor>
<dc:contributor>Universidad de Valladolid. Facultad de Ciencias</dc:contributor>
<dc:creator>Truchero Rodríguez, Tania</dc:creator>
<dc:date>2020</dc:date>
<dc:description>La ambliopía es una disminución de la visión cuyo origen se encuentra en un mal desarrollo del sistema visual. Su detección precoz ayuda a que los cambios que se producen en el sistema visual sean reversibles. La cuantificación de la estereopsis proporciona una medida de la fusión sensorial asociándose a un buen desarrollo visual. El objetivo principal de este trabajo es comparar las medidas tomadas con el nuevo software Visionary Tool® con los datos obtenidos mediante el uso de tres test clínicos: el Test de la mosca (Stereo Fly Test), el test estereoscópico de Randot y el Test TNO, así como calcular la repetibilidad del test presente en el software en estudio. Se realizaron tres medidas consecutivas del test de estereopsis presente en Visionary Tool®, además de una única medida de la estereopsis con los tres test clínicos incluidos en el estudio: TNO, Titmus test y Test de Randot. Para comprobar la validez de este nuevo test en estudio se ha analizado su repetibilidad intrasesión a través de varios parámetros: la desviación intrasesión (Sw), la precisión intrasesión (P), la repetibilidad, el coeficiente de variación (CV) y el coeficiente de correlación intraclase (CCI) y el acuerdo con otros test usando análisis de Bland and Altman.</dc:description>
<dc:description>Amblyopia is a decrease in visual acuity caused by incorrect development of the visual system. Early detection helps to avoid developmental defects in the visual system. The quantification of stereopsis provides a measure of sensory fusion associated with correct visual development. The main goal of this study is to compare the measurements taken with the new software Visionary Tool® with the data obtained with others three clinical tests: the Stereo Fly Test, the Randot stereoscopic test and the TNO test, as well as calculate the repeatability of the test present in the software under study.&#xd;
Three consecutive measurements of stereopsis with Visionary Tool® software were performed. In addition, one measurement of stereopsis was performed with three clinical tests: TNO, Titmus test and Random dot test. In order to verify the repeatability of this new test, it has been analyzed through several parameters: the intrasession deviation (Sw), the intrasession precision (P), repeatability, the coefficient of variation (CV) and the intraclass correlation coefficient (ICC) and agreement with other tests using Bland and Altman analysis.</dc:description>
<dc:format>application/pdf</dc:format>
<dc:identifier>http://uvadoc.uva.es/handle/10324/44978</dc:identifier>
<dc:language>spa</dc:language>
<dc:title>Repetibilidad y acuerdo entre métodos informáticos y tradicionales para la medida de la estereopsis</dc:title>
<dc:type>info:eu-repo/semantics/bachelorThesis</dc:type>
<edm:type>TEXT</edm:type>
</edm:ProvidedCHO>
<ore:Aggregation rdf:about="http://uvadoc.uva.es/handle/10324/44978#aggregation">
<edm:aggregatedCHO rdf:resource="http://uvadoc.uva.es/handle/10324/44978"/>
<edm:dataProvider>UVaDOC. Repositorio Documental de la Universidad de Valladolid</edm:dataProvider>
<edm:isShownAt rdf:resource="http://uvadoc.uva.es/handle/10324/44978"/>
<edm:isShownBy rdf:resource="https://uvadoc.uva.es/bitstream/10324/44978/1/TFG-G4714.pdf"/>
<edm:provider>Hispana</edm:provider>
<edm:rights rdf:resource="http://creativecommons.org/licenses/by-nc-nd/4.0/"/>
</ore:Aggregation>
<edm:WebResource rdf:about="https://uvadoc.uva.es/bitstream/10324/44978/1/TFG-G4714.pdf">
<edm:rights rdf:resource="http://creativecommons.org/licenses/by-nc-nd/4.0/"/>
</edm:WebResource>
</rdf:RDF></metadata></record></GetRecord></OAI-PMH>