<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T18:28:41Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/57902" metadataPrefix="qdc">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/57902</identifier><datestamp>2022-12-22T20:00:25Z</datestamp><setSpec>com_10324_1167</setSpec><setSpec>com_10324_931</setSpec><setSpec>com_10324_894</setSpec><setSpec>col_10324_1238</setSpec></header><metadata><qdc:qualifieddc xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
<dc:title>Assessment for the age-of-the-air and ventilation efficiency in confined outdoor spaces through computational fluid dynamics techniques</dc:title>
<dc:creator>Padilla Marcos, Miguel Ángel</dc:creator>
<dc:creator>Meiss Rodríguez, Alberto</dc:creator>
<dcterms:abstract>An experimentally validated numerical method for evaluating the suitability of an urban&#xd;
design with regard to its capacity to provide the optimum air quality for its occupants through the&#xd;
confined outdoor spaces is proposed. Eight possible confined outdoor spaces are defined according&#xd;
to their position with regard to the built elements, laterally delimited by the envelope surfaces of the&#xd;
neighbouring buildings. This work focuses on the definition of a procedure capable of analysing&#xd;
outdoor air change quality according to the age-of-the-air concept. The obtained results show that&#xd;
the confined outdoor spaces that are exposed to the wind action are more predisposed to reduce the&#xd;
mean age-of-the-air that they contain. For the analysed cases, a considerable improvement of up to&#xd;
78.68% in the air change quality can be obtained by taking into account wind exposure criteria in&#xd;
relation to its shape and urban density, which is classified for this purpose.</dcterms:abstract>
<dcterms:dateAccepted>2022-12-22T10:30:09Z</dcterms:dateAccepted>
<dcterms:available>2022-12-22T10:30:09Z</dcterms:available>
<dcterms:created>2022-12-22T10:30:09Z</dcterms:created>
<dcterms:issued>2018</dcterms:issued>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>Energies, 2018, vol. 11, n. 8, p. 1932</dc:identifier>
<dc:identifier>1996-1073</dc:identifier>
<dc:identifier>https://uvadoc.uva.es/handle/10324/57902</dc:identifier>
<dc:identifier>10.3390/en11081932</dc:identifier>
<dc:identifier>1932</dc:identifier>
<dc:identifier>8</dc:identifier>
<dc:identifier>Energies</dc:identifier>
<dc:identifier>11</dc:identifier>
<dc:identifier>1996-1073</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>https://www.mdpi.com/1996-1073/11/8/1932</dc:relation>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>http://creativecommons.org/licenses/by/4.0/</dc:rights>
<dc:rights>© 2018 The Author(s)</dc:rights>
<dc:rights>Atribución 4.0 Internacional</dc:rights>
<dc:publisher>MDPI</dc:publisher>
</qdc:qualifieddc></metadata></record></GetRecord></OAI-PMH>