<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-14T19:47:19Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/60358" metadataPrefix="mods">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/60358</identifier><datestamp>2023-07-19T10:09:59Z</datestamp><setSpec>com_10324_38</setSpec><setSpec>col_10324_852</setSpec></header><metadata><mods:mods xmlns:mods="http://www.loc.gov/mods/v3" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
<mods:name>
<mods:namePart>Vicente Merino, David</mods:namePart>
</mods:name>
<mods:extension>
<mods:dateAvailable encoding="iso8601">2023-07-17T15:12:00Z</mods:dateAvailable>
</mods:extension>
<mods:extension>
<mods:dateAccessioned encoding="iso8601">2023-07-17T15:12:00Z</mods:dateAccessioned>
</mods:extension>
<mods:originInfo>
<mods:dateIssued encoding="iso8601">2023</mods:dateIssued>
</mods:originInfo>
<mods:identifier type="uri">https://uvadoc.uva.es/handle/10324/60358</mods:identifier>
<mods:abstract>Una microrred es un conjunto de cargas y micro generadores que operan como un sistema&#xd;
único que provee energía eléctrica. Comprenden sistemas de distribución de baja tensión,&#xd;
fuentes de generación distribuida y otros dispositivos de almacenamiento. La operación&#xd;
coordinada de sus elementos puede proporcionar beneficios globales al sistema si se&#xd;
gestionan y coordinan de manera eficiente, mediante un buen controlador central del&#xd;
sistema, que está a la cabeza del sistema jerárquico de control. Una microrred puede&#xd;
funcionar de forma “aislada” o autónoma o interconectada a la Red Eléctrica Nacional.&#xd;
Cuando una microrred funciona en modo “aislado” de la red principal, los generadores&#xd;
tienen que ser capaces de responder con rapidez a los cambios en el consumo para que&#xd;
así tanto la tensión como la frecuencia se mantengan estables. El modo “conectado” de&#xd;
una microrred es ventajoso porque permite que la red principal proporcione las&#xd;
referencias de tensión y frecuencia necesarias para que el resto de los elementos funcionen&#xd;
sin problema alguno. Antes del emplazamiento y prueba de la microrred se deben seguir&#xd;
tres pasos fundamentales: la recopilación de datos, donde se obtienen datos de la&#xd;
demanda, de los recursos disponibles y del lugar donde se instala la microrred; el análisis&#xd;
de componentes del sistema, donde se seleccionan los componentes, según su fabricante,&#xd;
que más convengan a la microrred; y, la simulación del sistema, donde se realiza un&#xd;
análisis técnico y económico del funcionamiento de la microrred, además de una posible&#xd;
optimización del sistema. Para esta última etapa se puede utilizar software específico de&#xd;
simulación de microrredes.</mods:abstract>
<mods:abstract>A microgrid is a set of loads and micro generators that operate as a single system that&#xd;
provides electricity. They include low voltage distribution systems, distributed generation&#xd;
sources and other storage devices. The coordinated operation of its elements can provide&#xd;
global benefits to the system if they are managed and coordinated efficiently, by a good&#xd;
central system controller, who is at the head of the hierarchical control system. A&#xd;
microgrid can function in an "isolated" or autonomous way or interconnected to the&#xd;
National Electricity Network. When a microgrid operates in “isolated” mode from the&#xd;
main grid, the generators must be able to respond quickly to changes in consumption so&#xd;
that both voltage and frequency remain stable. The “connected” mode of a microgrid is&#xd;
advantageous because it allows the main network to provide the necessary voltage and&#xd;
frequency references for the rest of the elements to work without any problem. Before the&#xd;
placement and testing of the microgrid, three fundamental steps must be followed: data&#xd;
collection, where data on demand, available resources and the place where the microgrid&#xd;
is installed are obtained; the analysis of system components, where the components,&#xd;
according to their manufacturer, that are most convenient for the microgrid are selected;&#xd;
and, the simulation of the system, where a technical and economic analysis of the&#xd;
operation of the microgrid is carried out, as well as a possible optimization of the system.&#xd;
For this last stage, specific microgrid simulation software can be used.</mods:abstract>
<mods:language>
<mods:languageTerm>spa</mods:languageTerm>
</mods:language>
<mods:accessCondition type="useAndReproduction">info:eu-repo/semantics/openAccess</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">http://creativecommons.org/licenses/by-nc-nd/4.0/</mods:accessCondition>
<mods:accessCondition type="useAndReproduction">Attribution-NonCommercial-NoDerivatives 4.0 Internacional</mods:accessCondition>
<mods:titleInfo>
<mods:title>Herramienta gráfica para la divulgación de micro redes</mods:title>
</mods:titleInfo>
<mods:genre>info:eu-repo/semantics/bachelorThesis</mods:genre>
</mods:mods></metadata></record></GetRecord></OAI-PMH>