<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T19:37:30Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/61520" metadataPrefix="dim">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/61520</identifier><datestamp>2025-02-20T08:23:41Z</datestamp><setSpec>com_10324_40357</setSpec><setSpec>com_10324_952</setSpec><setSpec>com_10324_894</setSpec><setSpec>col_10324_40358</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="cccbebf247451cbb" confidence="600" orcid_id="">Fernández Bueno, Iván</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="0e6a896a-c456-45a0-82b6-9161877a620f">Olcina, Luis Ignacio</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="bb7eca803fb08865" confidence="600" orcid_id="0000-0002-4010-3923">Andrés Iglesias, Cristina</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="0a20bc7a409e2b30" confidence="600" orcid_id="0000-0002-9641-4042">Puertas Neyra, Kevin Louis</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="551de6a278d8099e" confidence="600" orcid_id="0000-0002-5077-4448">Fernández Martínez, Itziar</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="1460ea1860384eb0" confidence="600" orcid_id="">Usategui Martín, Ricardo</dim:field>
<dim:field mdschema="dc" element="contributor" qualifier="author" authority="5ab9a9feec11d91f" confidence="600" orcid_id="0000-0002-1021-3275">Maldonado López, Miguel José</dim:field>
<dim:field mdschema="dc" element="date" qualifier="accessioned">2023-09-12T07:13:15Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="available">2023-09-12T07:13:15Z</dim:field>
<dim:field mdschema="dc" element="date" qualifier="issued">2023</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="citation" lang="es">Heliyon, 2023, vol. 9, issue 9, e19604</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="issn" lang="es">2405-8440</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="uri">https://uvadoc.uva.es/handle/10324/61520</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="doi" lang="es">10.1016/j.heliyon.2023.e19604</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationfirstpage" lang="es">e19604</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationissue" lang="es">9</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationtitle" lang="es">Heliyon</dim:field>
<dim:field mdschema="dc" element="identifier" qualifier="publicationvolume" lang="es">9</dim:field>
<dim:field mdschema="dc" element="description" lang="es">Producción Científica</dim:field>
<dim:field mdschema="dc" element="description" qualifier="abstract" lang="es">This study aims to evaluate the safety, biocompatibility, and functionality of a new accommodative intraocular lens (IOL) (LUZ, patent PCT/ES2016/070,813) after implantation in rabbit eyes. LUZ (Study) and EyeCee® plus a capsular ring (Control) were implanted in rabbits (n = 8 each) after phacoemulsification. Intraoperative follow-up, long-term clinical follow-up, and functional IOL studies were carried out periodically for up to 180 days. A macroscopic examination of the eyeballs to reveal abnormalities and determine the implant centering and a microscopic examination to semi-quantify cell and tissue response were performed. Statistical analysis of the collected data was finally achieved. During follow-up, no significant changes in the general condition nor the clinical evaluation were observed between both groups. However, Study IOL remained centered throughout the study and did not present severe complications as observed in the Control group. Functional studies did not reveal significant differences between both materials. Study showed better centering, fewer adhesions, and maintenance of an opening capsular bag compared to the Control. Local biological effects caused by Study implantation are minimal and comparable to the Control. Therefore, LUZ showed no clinical signs or histological response of adverse reaction to the implanted material, according to UNE-EN ISO 11979-5 and 10993-6. Functionality must be confirmed in another animal species with greater lens accommodation capacity than the rabbit. LUZ keeps the capsular bag open, favoring its centering and avoiding fibrosis and adherence to the bag; this allows potential accommodation of this IOL and theoretically enables the patient to focus dynamically.</dim:field>
<dim:field mdschema="dc" element="description" qualifier="project">Ministerio de Ciencia e Innovación (Neotec Project EXP-00104711/SNEO-20171172)</dim:field>
<dim:field mdschema="dc" element="format" qualifier="mimetype" lang="es">application/pdf</dim:field>
<dim:field mdschema="dc" element="language" qualifier="iso" lang="es">eng</dim:field>
<dim:field mdschema="dc" element="publisher" lang="es">Elsevier</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="accessRights" lang="es">info:eu-repo/semantics/openAccess</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="uri" lang="*">http://creativecommons.org/licenses/by-nc-nd/4.0/</dim:field>
<dim:field mdschema="dc" element="rights" qualifier="holder" lang="es">© 2023 The Authors</dim:field>
<dim:field mdschema="dc" element="rights" lang="*">Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Eye Diseases</dim:field>
<dim:field mdschema="dc" element="subject" lang="es">Oftalmología</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Presbyopia</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Intraocular lens</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Biocompatibility</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Presbicia</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Lente intraocular</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="classification" lang="es">Biocompatibilidad</dim:field>
<dim:field mdschema="dc" element="subject" qualifier="unesco" lang="es">3201.09 Oftalmología</dim:field>
<dim:field mdschema="dc" element="title" lang="es">Safety, biocompatibility, and potential functionality of a new accommodative intraocular lens: An experimental study in rabbits</dim:field>
<dim:field mdschema="dc" element="type" lang="es">info:eu-repo/semantics/article</dim:field>
<dim:field mdschema="dc" element="type" qualifier="hasVersion" lang="es">info:eu-repo/semantics/publishedVersion</dim:field>
<dim:field mdschema="dc" element="relation" qualifier="publisherversion" lang="es">https://www.sciencedirect.com/science/article/pii/S2405844023068123?via%3Dihub</dim:field>
<dim:field mdschema="dc" element="peerreviewed" lang="es">SI</dim:field>
</dim:dim></metadata></record></GetRecord></OAI-PMH>