<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T10:09:49Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/64600" metadataPrefix="rdf">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/64600</identifier><datestamp>2025-01-31T12:42:22Z</datestamp><setSpec>com_10324_1138</setSpec><setSpec>com_10324_931</setSpec><setSpec>com_10324_894</setSpec><setSpec>com_10324_40357</setSpec><setSpec>com_10324_952</setSpec><setSpec>col_10324_1226</setSpec><setSpec>col_10324_40358</setSpec></header><metadata><rdf:RDF xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
<ow:Publication rdf:about="oai:uvadoc.uva.es:10324/64600">
<dc:title>Reliability and agreement of subjective and objective non‐invasive break‐up time measurements in contact lens wearers</dc:title>
<dc:creator>Valencia Nieto, Laura</dc:creator>
<dc:creator>López De La Rosa, Alberto</dc:creator>
<dc:creator>González García, María Jesús</dc:creator>
<dc:creator>López Miguel, Alberto</dc:creator>
<dc:description>Producción Científica</dc:description>
<dc:description>Purpose&#xd;
&#xd;
To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques.&#xd;
Methods&#xd;
&#xd;
In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within-subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland–Altman method.&#xd;
Results&#xd;
&#xd;
A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA-800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA-800 device provided significantly (p &lt; 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups.&#xd;
Conclusion&#xd;
&#xd;
Objective (CA-800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations.</dc:description>
<dc:date>2024-01-16T13:53:22Z</dc:date>
<dc:date>2024-01-16T13:53:22Z</dc:date>
<dc:date>2023</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:identifier>Ophthalmic and Physiological Optics, 2023, vol. 44, n. 1, p. 124-130</dc:identifier>
<dc:identifier>0275-5408</dc:identifier>
<dc:identifier>https://uvadoc.uva.es/handle/10324/64600</dc:identifier>
<dc:identifier>10.1111/opo.13243</dc:identifier>
<dc:identifier>124</dc:identifier>
<dc:identifier>1</dc:identifier>
<dc:identifier>130</dc:identifier>
<dc:identifier>Ophthalmic and Physiological Optics</dc:identifier>
<dc:identifier>44</dc:identifier>
<dc:identifier>1475-1313</dc:identifier>
<dc:language>eng</dc:language>
<dc:relation>https://onlinelibrary.wiley.com/doi/10.1111/opo.13243</dc:relation>
<dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
<dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
<dc:rights>© 2023 The Author(s)</dc:rights>
<dc:rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dc:rights>
<dc:publisher>Wiley</dc:publisher>
<dc:peerreviewed>SI</dc:peerreviewed>
</ow:Publication>
</rdf:RDF></metadata></record></GetRecord></OAI-PMH>