<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T18:30:25Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/69364" metadataPrefix="etdms">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/69364</identifier><datestamp>2024-10-02T08:08:39Z</datestamp><setSpec>com_10324_38</setSpec><setSpec>col_10324_852</setSpec></header><metadata><thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.0/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>Instalación eléctrica en una nave industrial e instalación fotovoltaica</title>
<creator>Villanueva Muñoz, Enrique</creator>
<contributor>Muñoz Cano, Manuel</contributor>
<contributor>Pérez García, Julián Manuel</contributor>
<contributor>Universidad de Valladolid. Escuela de Ingenierías Industriales</contributor>
<description>Este trabajo fin de grado, se centra en el diseño de la instalación eléctrica y&#xd;
fotovoltaica de una nave industrial con actividad como taller metalúrgico,&#xd;
ubicada en Villanubla, Valladolid.&#xd;
Al ser un taller metalúrgico no existe un proceso productivo en sentido estricto,&#xd;
si no que en todo el momento el trabajo se va adaptando según la demanda&#xd;
del taller.&#xd;
Se ha realizado un estudio de cargas de la nave, y a partir de dicho estudio se&#xd;
ha diseñado el esquema unifilar, repartiendo las cargas de la forma más&#xd;
eficiente. Sumando una potencia total de 307,6 kW.&#xd;
Respecto a la instalación fotovoltaica, se han analizado los consumos del taller&#xd;
a lo largo de un año, y a partir de este análisis se ha hecho un estudio&#xd;
energético, económico y técnico para estimar la potencia óptima, siendo está&#xd;
de 47,5 kWp, con un total de 108 paneles de 440 Wp. El objetivo principal es&#xd;
reducir la facturación de energía eléctrica, acogiéndose a la modalidad con&#xd;
compensación y favorecer al medioambiente al autoabastecerse de energía&#xd;
limpia y renovable.</description>
<description>This final degree project focuses on the design of the electrical and photovoltaic&#xd;
installation of an industrial warehouse with activity as a metallurgical workshop,&#xd;
located in Villanubla, Valladolid.&#xd;
Being a metallurgical workshop, there is no production process in the strict sense, but&#xd;
at all times the work is adapted according to the demand of the workshop.&#xd;
A study of the ship's loads was carried out, and from this study the single-line scheme&#xd;
was designed, distributing the loads in the most efficient way. Adding a total power of&#xd;
307.6 kW.&#xd;
Regarding the photovoltaic installation, the workshop consumption has been analyzed&#xd;
over the course of a year, and based on this analysis an energy, economic and technical&#xd;
study has been carried out to estimate the most optimal power, which is 47.5 kWp. with&#xd;
a total of 108 panels of 440 Wp. The objective being to reduce the billing of electrical&#xd;
energy, taking advantage of the modality with compensation and favoring the&#xd;
environment by self-supplying clean and renewable energy.</description>
<date>2024-08-20</date>
<date>2024-08-20</date>
<date>2024</date>
<type>info:eu-repo/semantics/bachelorThesis</type>
<identifier>https://uvadoc.uva.es/handle/10324/69364</identifier>
<language>spa</language>
<rights>info:eu-repo/semantics/openAccess</rights>
<rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</rights>
<rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</rights>
</thesis></metadata></record></GetRecord></OAI-PMH>