<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-05T19:25:41Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/78634" metadataPrefix="uketd_dc">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/78634</identifier><datestamp>2025-10-14T19:03:13Z</datestamp><setSpec>com_10324_38</setSpec><setSpec>col_10324_852</setSpec></header><metadata><uketd_dc:uketddc xmlns:uketd_dc="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:uketdterms="http://naca.central.cranfield.ac.uk/ethos-oai/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:dc="http://purl.org/dc/elements/1.1/" xsi:schemaLocation="http://naca.central.cranfield.ac.uk/ethos-oai/2.0/ http://naca.central.cranfield.ac.uk/ethos-oai/2.0/uketd_dc.xsd">
<dc:title>El efecto Talbot y la difracción de Fresnel</dc:title>
<dc:creator>Corral Barbero, Néstor</dc:creator>
<uketdterms:advisor>Pérez Callejo, Gabriel</uketdterms:advisor>
<dcterms:abstract>Los rayos X son famosamente conocidos por ser radiación electromagnética muy penetrante que permite&#xd;
tomar imágenes sensibles a absorción en diagnosis médica.&#xd;
Las técnicas de imagen por absorción de rayos X son, por lo tanto particularmente útiles en sistemas&#xd;
con componentes cuya absorción sean suficientemente distitna entre unos y otros. No obstante, en el&#xd;
caso de que sean similares estos valores, el usuario queda obligado a emplear tiempos de irradiación e&#xd;
intensidades mucho mayores, resultando en un estudio mucho menos eficiente.&#xd;
Este trabajo versa sobre una alternativa a estos métodos, que en lugar de la parte imaginaria del índice&#xd;
de refracción, emplea su parte real para obtener imágenes de diversos materiales y obtener magnitudes&#xd;
relevantes. Esta técnica recibe el nombre de interferometría Talbot.</dcterms:abstract>
<dcterms:abstract>X-rays are a highly penetrating form of electromagnetic radiation that owe their fame to its use on&#xd;
clinical imaging.&#xd;
These imaging sistems capitalize de low X-ray absorption by most materials. Therefore, its usefulness&#xd;
becomes evident upon studying systems with enough variance on absorption coefficients. However, this&#xd;
is not always the case, and when absorption coefficients within a sample are similar enough, higher&#xd;
dosage is required, which is far from ideal.&#xd;
This dissertation features an alternative imaging technique centered around the phase shift an object&#xd;
introduces to an incoming X-ray beam: Talbot interferometry. In other words, rather than working&#xd;
with the attenuation image that stems from working with the imaginary component of the refraction&#xd;
index, we shall use the real part of this parameter to recreate object images.</dcterms:abstract>
<dcterms:issued>2025</dcterms:issued>
<dc:type>info:eu-repo/semantics/bachelorThesis</dc:type>
<dc:language xsi:type="dcterms:ISO639-2">spa</dc:language>
<uketdterms:sponsor>Departamento de Física Teórica, Atómica y Óptica</uketdterms:sponsor>
<dcterms:isReferencedBy>https://uvadoc.uva.es/handle/10324/78634</dcterms:isReferencedBy>
<dcterms:license>https://uvadoc.uva.es/bitstream/10324/78634/3/license.txt</dcterms:license>
<uketdterms:checksum xsi:type="uketdterms:MD5">289d98c1665ee0d20312360f0e8643c8</uketdterms:checksum>
<dc:identifier xsi:type="dcterms:URI">https://uvadoc.uva.es/bitstream/10324/78634/1/TFG-G7571.pdf</dc:identifier>
<uketdterms:checksum xsi:type="uketdterms:MD5">9c188660f836a1e2a9ab627759445997</uketdterms:checksum>
<dc:rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dc:rights>
</uketd_dc:uketddc></metadata></record></GetRecord></OAI-PMH>