<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-04-29T11:00:24Z</responseDate><request verb="GetRecord" identifier="oai:uvadoc.uva.es:10324/79370" metadataPrefix="etdms">https://uvadoc.uva.es/oai/request</request><GetRecord><record><header><identifier>oai:uvadoc.uva.es:10324/79370</identifier><datestamp>2025-11-06T20:08:13Z</datestamp><setSpec>com_10324_38</setSpec><setSpec>col_10324_852</setSpec></header><metadata><thesis xmlns="http://www.ndltd.org/standards/metadata/etdms/1.0/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.ndltd.org/standards/metadata/etdms/1.0/ http://www.ndltd.org/standards/metadata/etdms/1.0/etdms.xsd">
<title>Desarrollo de una ontología y creación de un servicio para la gestión eficiente de la energía en edificios</title>
<creator>Jiménez García, Daniel</creator>
<contributor>Cámara Moreno, Jesús</contributor>
<contributor>Gutiérrez Caballero, Susana María</contributor>
<contributor>Universidad de Valladolid. Escuela de Ingeniería Informática de Valladolid</contributor>
<description>En este trabajo, se ha desarrollado una ontología en base a la integración de conceptos de&#xd;
SAREF y su extensión SAREF for Building. La ontología generada a partir del mapping de los&#xd;
elementos de nidos en un  chero IFC sirve como modelo de datos para la autocon guración de&#xd;
un servicio de climatización. Se ha tratado que este servicio de auton guración fuera agnóstico&#xd;
y las consultas sean delegadas en otra capa que si sea dependiente de dicho modelo. Aunque la&#xd;
conversión de los sensores y actuadores funcionan para cualquier tipo de estos de nidos en la&#xd;
semántica de IFC, el servicio, a través del ingestor de datos IFC, únicamente mapea los sensores&#xd;
de temperatura, humedad y CO2.&#xd;
Las pruebas realizadas han involucrado la obtención de datos del edi cio de CARTIF3 a través de  cheros CSV debido a que no se ha podido ejecutar una prueba real en el edi cio. Por&#xd;
este motivo las actuaciones necesarias que habría que realizar se ven por consola. Para terminar&#xd;
de comprobar que la autocon guración es útil en más edi cios y que no se trata de una solución&#xd;
ad hoc en el edi cio de CARTIF3, se ha creado una demo a partir de otro  chero IFC descargado de internet. En esta demo, como no se disponían de datos previos, se ha implementado una&#xd;
función para generar predicciones de temperatura que posteriormente se insertan en una base de&#xd;
datos alojada en una máquina virtual de Oracle Cloud Infrastructure y simular una arquitectura&#xd;
parecida a la que se tendría en un entorno real.</description>
<description>In this work, an ontology has been developed based on integrating concepts from SAREF and&#xd;
its extension, SAREF for Building. The ontology generated from the mapping of elements de ned&#xd;
in an IFC  le subsequently serves as a data model for the auto-con guration of a climate control&#xd;
service. E orts have been made to ensure this auto-con guration service remains agnostic, delegating queries to another layer that depends explicitly on the data model. Although the sensor&#xd;
and actuator conversion works for any type de ned in the IFC semantics, the service, through the&#xd;
IFC data ingestor, only maps temperature, humidity, and CO2 sensors.&#xd;
The tests conducted involved obtaining building data from CARTIF3 through CSV  les because&#xd;
it was not possible to execute a real test in the building itself. Therefore, the required actions&#xd;
are displayed in the console. To further con rm that auto-con guration is e ective in multiple&#xd;
buildings and not a solution tailored speci cally for the CARTIF3 building, a demo has been&#xd;
created using another IFC  le downloaded from the internet. In this demo, due to the lack of&#xd;
previous data, a function has been implemented to generate temperature predictions, which are&#xd;
subsequently inserted into a database hosted on an Oracle Cloud Infrastructure virtual machine,&#xd;
simulating an architecture similar to one that would exist in a real environment.</description>
<date>2025-11-06</date>
<date>2025-11-06</date>
<date>2025</date>
<type>info:eu-repo/semantics/bachelorThesis</type>
<identifier>https://uvadoc.uva.es/handle/10324/79370</identifier>
<language>spa</language>
<rights>info:eu-repo/semantics/openAccess</rights>
<rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</rights>
<rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</rights>
</thesis></metadata></record></GetRecord></OAI-PMH>