RT info:eu-repo/semantics/article T1 Improved performance of a PV integrated ventilated façade at an existing nZEB A1 Tejero González, Ana A1 Krawczyk, Dorota Anna A1 Rey Martínez, Francisco Javier A1 Velasco Gómez, Eloy K1 Photovoltaics K1 Energía fotovoltaica AB Ventilated façades are among the existing measures to reduce the energy demand in buildings. The combination of this passive heating and cooling strategy with photovoltaics (PV) can drive new buildings towards the current European targets for near or even net zero-energy buildings (nZEB). The present work aims at studying the PV integrated ventilated façade of the nZEB known as “LUCIA” at the University of Valladolid, Spain. First, the transmissivity of the PV façade is measured. Then, the monitoring of the available solar radiation is presented together with the air-dry bulb temperatures indoors, outdoors and inside the ventilated façade. The experimental results permit the validation of a mathematical model that describes the behaviour of the ventilated façade in its current operating modes. The results show that dampers should be closed during winter to let the façade act as a further insulation for outdoor temperatures below 18.4 C to improve energy efficiency. Indoor air recirculation would be helpful during 10% of the winter period. PB MDPI SN 2504-3900 YR 2019 FD 2019 LK https://uvadoc.uva.es/handle/10324/55879 UL https://uvadoc.uva.es/handle/10324/55879 LA eng NO Proceedings, 2019, vol. 16, n. 1, 22 NO Producción Científica DS UVaDOC RD 23-nov-2024