RT info:eu-repo/semantics/article T1 Comparative assessment of a biofilter, a biotrickling filter and a hollow fiber membrane bioreactor for odor treatment in wastewater treatment plants A1 Lebrero Fernández, Raquel A1 Gondim, Ana Celina A1 Pérez Fernández, Rebeca A1 García Encina, Pedro Antonio A1 Muñoz Torre, Raúl AB A low abatement efficiency for the hydrophobic fraction of odorous emissions and a high footprint are often pointed out as the major drawbacks of conventional biotechnologies for odor treatment. In this work, two conventional biotechnologies (a compost-based biofilter, BF, and a biotrickling filter, BTF), and a hollow-fiber membrane bioreactor (HF-MBR) were comparatively evaluated in terms of odor abatement potential and pressure drop (ΔP) at empty bed residence times (EBRTs) ranging from 4 to 84 s, during the treatment of methyl-mercaptan, toluene, alpha-pinene and hexane at trace level concentrations (0.75–4.9 mg m−3). High removal efficiencies (RE > 90% regardless of the air pollutant) were recorded in the BF at EBRTs ≥ 8 s, although the high ΔP across the packed bed limited its cost-effective operation to EBRTs > 19 s. A complete methyl-mercaptan, toluene and alpha-pinene removal was recorded in the BTF at EBRTs ≥ 4 s and ΔP lower than 33 mmH2O (∼611 Pa mbed−1), whereas slightly lower REs were observed for hexane (∼88%). The HF-MBR completely removed methyl-mercaptan and toluene at all EBRTs tested, but exhibited an unstable alpha-pinene removal performance as a result of biomass accumulation and a low hexane abatement efficiency. Thus, a periodical membrane-cleaning procedure was required to ensure a steady abatement performance. Finally, a high bacterial diversity was observed in the three bioreactors in spite of the low carbon source spectrum present in the air emission. SN 0043-1354 YR 2014 FD 2014 LK https://uvadoc.uva.es/handle/10324/64834 UL https://uvadoc.uva.es/handle/10324/64834 LA spa NO Volume 49, 1 February 2014, Pages 339-350 DS UVaDOC RD 09-may-2025