RT info:eu-repo/semantics/article T1 A Power-Line Communication System Governed by Loop Resonance for Photovoltaic Plant Monitoring A1 Morales-Aragones, José Ignacio A1 Williams, Matthew St. Michael A1 Kupolati, Halleluyah A1 Alonso-Gómez, Víctor A1 Gallardo-Saavedra, Sara A1 Redondo-Plaza, Alberto A1 Muñoz-García, Miguel Ángel A1 Sánchez-Pacheco, Francisco José A1 Hernández Callejo, Luis AB Within this paper, a PLC system that takes advantage of the loop resonance of an entire DC-PV string configured as a circular signal path is developed and implemented. Low cost and extremely simple transceivers intended to be installed within each PV module of a string have been designed and successfully tested. In addition, an anti-saturation coil has been conceived to avoid saturation of the core when the entire DC current of the string flows through it. Bi-directional half-duplex communication was successfully executed with up to a 1 MHz carrier frequency (150 kbps bitrate), using a simple ASK modulation scheme. The transmission and reception performance are presented, along with the overall system cost in comparison to the previous literature. YR 2022 FD 2022 LK https://uvadoc.uva.es/handle/10324/66115 UL https://uvadoc.uva.es/handle/10324/66115 LA spa NO Morales-Aragones, J.I.; Williams, M.S.M.; Kupolati, H.; Alonso-Gómez, V.; Gallardo-Saavedra, S.; Redondo-Plaza, A.; Muñoz-García, M.Á.; Sánchez-Pacheco, F.J.; Hernández-Callejo, L. A Power-Line Communication System Governed by Loop Resonance for Photovoltaic Plant Monitoring. Sensors 2022, 22, 9207. https://doi.org/10.3390/s22239207 DS UVaDOC RD 27-dic-2024