RT info:eu-repo/semantics/article T1 Assessment of the risk of surface condensation on cultural heritage mechanical brick facades: the importance of surface temperature measurement. The case of a historic building in Valladolid. A1 Rodríguez Esteban, María Ascensión A1 Camino Olea, María Soledad A1 Sáez Pérez, María Paz A1 Ramón Cueto, Gemma A1 Bellido Pla, Rosa Luz K1 Construcción, Ladrillo, Condensación superficial, Patrimonio histórico, Flujo térmico K1 brick; cultural heritage; surface condensation; moisture; thermal flow test K1 3305.01 Diseño Arquitectónico K1 3305.90 Transmisión de Calor en la Edificación AB The assessment of the risk of surface condensation on the walls of Cultural Heritage buildings is crucial, since it has been identified that the analytical method used for new buildings can generate errors in these properties. The objective of this research is therefore focused on comparing the differences in surface temperatures between those calculated by the analytical method and those obtained by the in situ measurement. For its determination, the ambient and surface temperatures of the facade of a historic building have been measured, and heat flow tests have been carried out to estimate the conductivity of the walls. By contrasting the results obtained with the data calculated from the analytical system, it is concluded that this method is not entirely valid for this type of building. PB Ángel Castillo Talavera, José Luis García Calvo, Enio J. Pazini Figueiredo y Pedro Castro Borges YR 2025 FD 2025 LK https://uvadoc.uva.es/handle/10324/78726 UL https://uvadoc.uva.es/handle/10324/78726 LA spa NO MEMORIAS CONPAT2025 XVIII Congreso Iberoamericano de Patología de la Construcción XX Congreso de Control de Calidad en la Construcción, 2025, p. 616-627- NO Producción Científica DS UVaDOC RD 27-oct-2025