TY - CHAP AU - Gallardo Saavedra, Sara AU - Moretón Fernández, Ángel AU - Jiménez Martín, Marta María AU - Alonso Gómez, Víctor AU - Hernández Callejo, Luis AU - Martínez Sacristán, Óscar AU - González Rebollo, Miguel Ángel AU - Morales Aragones, José Ignacio PY - 2019 SN - 3-936338-60-4 UR - https://uvadoc.uva.es/handle/10324/52886 AB - Different techniques can be used to detect and quantify PV modules anomalies, as visual inspections, electrical tests like the I-V curve test, infrared thermography (IRT) or electroluminescence (EL). PV plants operators usually apply only one or two... LA - eng TI - Failure diagnosis on photovoltaic modules using thermography, electroluminescence, Rgb and I-V techniques ER -