TY - JOUR AU - Lorenzana Ibán, Antolín AU - Villacorta Calvo, Juan José AU - Magdaleno González, Álvaro AU - Val Puente, Lara del AU - Izquierdo Fuente, Alberto PY - 2024 SN - 2075-5309 UR - https://uvadoc.uva.es/handle/10324/68288 AB - Preserved listed building facades may require large-scale and highly technical work when the supporting building structure is at serious risk of collapse. Such is the case described in this paper, where vast facades must be cut into large panels up to... LA - eng PB - MDPI KW - Cultural property - Protection KW - Bienes culturales - Protección KW - Buildings - Repair and reconstruction KW - Edificios - Reparación y reconstrucción KW - Historic buildings - Conservation and restoration KW - Monumentos históricos - Conservación y restauración KW - Deconstruction KW - Deconstrucción KW - Structural health monitoring KW - Construction industry -- Safety measures KW - Construcción - Seguridad - Medidas KW - Vibration KW - Shock (Mechanics) KW - Colisiones (Física) KW - Cultural heritage KW - Patrimonio cultural KW - Facades - Design and construction KW - Fachadas - Diseño y construcción TI - Design of an instant vibration-based warning system and Its operation during relocation works of historic facades DO - 10.3390/buildings14071889 ER -