Mostrar registro simples

dc.contributor.authorDuque Pérez, Óscar 
dc.contributor.authorGarcía Escudero, Luis Ángel 
dc.contributor.authorMoríñigo Sotelo, Daniel 
dc.contributor.authorGardel Sotomayor, Pedro Esteban
dc.contributor.authorPérez Alonso, Marcelo
dc.date.accessioned2015-12-16T10:53:22Z
dc.date.available2015-12-16T10:53:22Z
dc.date.issued2015
dc.identifier.urihttp://uvadoc.uva.es/handle/10324/15090
dc.descriptionProducción Científicaes
dc.description.abstractCondition monitoring of induction motors fed by Voltage Source Inverters is challenging since the influence of the supply complicates the use of methods valid for utility fed motors. When trying to obtain a fault detection scheme valid for any kind of supply and at any operating frequency is necessary to analyze the influence of the different operating conditions. To obtain generic conclusions, a statistical analysis has been performed over the data obtained in a controlled laboratory experiment where a hole was progressively drilled into a rotor bar. Additive models have been obtained to stand out the influence of the operating conditions over the fault signatures. Conclusions useful for condition monitoring are drawn.es
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.subjectEstadística. Ingeniería.es
dc.titleAnalysis of Fault Signatures for the Diagnosis of Induction Motors fed by Voltage Source Inverters using ANOVA and Additive Modelses