Mostrar el registro sencillo del ítem

dc.contributor.authorKhaydukova, María
dc.contributor.authorMedina Plaza, Cristina
dc.contributor.authorRodríguez Méndez, María Luz 
dc.contributor.authorPanchuka, Vitaly
dc.contributor.authorKirsanov, Dmitry
dc.contributor.authorLegin, Andrey Andrey V.
dc.date.accessioned2017-06-19T14:57:18Z
dc.date.issued2017
dc.identifier.citationSensors and Actuators B, 2017, vol. 246, p. 994–1000es
dc.identifier.urihttp://uvadoc.uva.es/handle/10324/23552
dc.descriptionProducción Científicaes
dc.description.abstractThe most popular sensors in multisensor systems (electronic tongues) are voltammetric and potentiometric ones. Practical application of multisensor systems for evaluation of particular target parameters requires calibration step. Even if both types of sensors (voltammetric and potentiometric) can be sensitive towards the same parameter of an analyte and can be used for its quantification, corresponding multisensor systems cannot operate in the framework of a single unified calibration model interpreting the responses of both systems. This research is dedicated to experimental verification of calibration transfer feasibility between voltammetric and potentiometric multisensor systems. The algorithm of direct standardization suggested earlier in spectroscopy was applied for transformation of potentiometric data into voltammetric format, and vice versa. Such transformations allowed for interpretation of a system response by multivariate regression model built employing the data from another type of multisensor system. For example, concentration of the tartaric acid in the grape musts can be determined with the regression model developed for voltammetric system using the data obtained from potentiometric system. Only 20% decrease in precision was observed for the converted potentiometric data compared to initial voltammetric model.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherElsevieres
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses
dc.subject.classificationMultisensor systemes
dc.subject.classificationElectronic tonguees
dc.subject.classificationCalibration transferes
dc.titleMultivariate calibration transfer between two different types of multisensor systemses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holderElsevieres
dc.identifier.doi10.1016/j.snb.2017.02.099es
dc.identifier.publicationfirstpage994es
dc.identifier.publicationlastpage1000es
dc.identifier.publicationtitleSensors and Actuators Bes
dc.identifier.publicationvolume246es
dc.peerreviewedSIes
dc.description.embargo2220-12-31es
dc.description.lift2220-12-31
dc.description.projectM. Khaydukova acknowledges joint scholarship program of St. Petersburg State University and Bank Santander.es
dc.description.projectM. Khaydukova and A. Legin acknowledge partial financial support of this study from St. Petersburg State University research grant #12.37.216.2016.es
dc.description.projectD. Kirsanov acknowledges partial financial support of his work by the Government of Russian Federation, Grant 074-U01.es
dc.description.projectFinancial support by MINECO and FEDER (AGL2015- 67482-R).es
dc.description.projectJunta de Castilla y León-FEDER (VA011U16).es
dc.description.projectC. Medina-Plaza thanks the University of Valladolid for a PIF UVA scholarship.es