• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UVaDOCCommunitiesBy Issue DateAuthorsSubjectsTitles

    My Account

    Login

    Statistics

    View Usage Statistics

    Share

    View Item 
    •   UVaDOC Home
    • FINAL DEGREE PROJECTS
    • Trabajos Fin de Grado UVa
    • View Item
    •   UVaDOC Home
    • FINAL DEGREE PROJECTS
    • Trabajos Fin de Grado UVa
    • View Item
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Export

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:http://uvadoc.uva.es/handle/10324/44390

    Título
    Repetibilidad y acuerdo entre métodos informáticos y tradicionales para la medida de la sensibilidad al contraste
    Autor
    González Villoria, Álvaro
    Director o Tutor
    Sánchez Pavón, IreneAutoridad UVA
    Editor
    Universidad de Valladolid. Facultad de CienciasAutoridad UVA
    Año del Documento
    2020
    Titulación
    Grado en Óptica y Optometría
    Abstract
    La sensibilidad al contraste (SC) evalúa la capacidad visual de un individuo expuesto a diferentes niveles de contraste. Una disminución de la misma puede ser indicativa de patología ocular como la ambliopía. Existen actualmente diferentes test de medida de la SC, siendo el objeto de este estudio analizar la repetibilidad de Visionary en comparación con el CSV-1000. Se realizaron 3 medidas de SC con Visionary y 1 con CSV-1000, en 26 voluntarios que participaron en el estudio, todos ellos sin problemas patológicos que pudieran afectar a su SC y con su corrección necesaria para alcanzar Agudeza visual (AV) superior a 0,8.
     
    Contrast sensitivity (CS) assesses the visual function capacity of a person exposed to different levels of contrast. A decrease may indicate ocular pathology, such as amblyopia. There are different CS measuring devices, the purpose of this study is to analyze the repeatability of Visionary and agreement to the CSV-1000. It was made 3 Visionary measurements and 1 CSV-1000 test, in this order: One from Visionary, one from CSV-1000 and then two consecutive from Visionary, in 26 patients who participated in the study, all of them without pathological problems related to CS and with its necessary correction to reach AV higher than 0,8.
    Palabras Clave
    Sensibilidad al contraste
    Repetibilidad y sensibilidad
    Idioma
    spa
    URI
    http://uvadoc.uva.es/handle/10324/44390
    Derechos
    openAccess
    Collections
    • Trabajos Fin de Grado UVa [31012]
    Show full item record
    Files in this item
    Nombre:
    TFG-G4698.pdf
    Tamaño:
    928.5Kb
    Formato:
    Adobe PDF
    Thumbnail
    FilesOpen
    Attribution-NonCommercial-NoDerivatives 4.0 InternacionalExcept where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10