Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/58290
Título
Performance critical comparison of offline SPE, online SPE, and direct injection for the determination of CECs in complex liquid environmental matrices
Autor
Año del Documento
2023
Editorial
Elsevier
Descripción
Producción Científica
Documento Fuente
Microchemical Journal, 2023, vol. 187, p. 108395
Abstract
Sample preparation for the analysis of organic micropollutants in wastewater samples is commonly carried out by solid-phase extraction (SPE) procedures, which involve different manual laboratory operations. This conventional approach requires several hours of counter labour and entail the use of a lot of disposable material, and the subsequent contaminated non-recyclable plastic-residue production. In contrast, by coupling and automatizing the pre-treatment to the instrumental analysis most of that burden erases, sample size gets miniaturized and, thus, storage becomes freed-up. Even lab counters get cleared off from sample pre-treatment apparatus. However, method performance could get alter as a trade-off. This paper presents the results from a study in which methodology, including SPE online-coupled to UHPLC-MS/MS chromatography, was developed for multi-residue (58) determination of veterinary and pharmaceutical drugs in urban and piggery wastewater (influent and effluent to wastewater treatment plants (WWTPs)). Similarly, the direct injection (DI) of large volumes (hundreds of µL) of same matrix samples into the chromatographic system was optimized too. The performance of both automated methods was statistically compared with the classical off-line SPE. As dealing with trace analysis, suitable injection volumes for the alternative approaches were selected on the premise of low limits of quantification (MLQs). Under the selected conditions, validation parameters such as linearity range, method quantification limits, peak shape and carry over were determined. Usually more than 50 % of the analytes showed MLQs below 50 ng/L, for all matrices and methodologies, especially for DI. Real wastewater samples from a local urban WWTP and farm were analysed with all three tested methodologies. Determined concentrations and removal rates were statistically compared and turned out being quite similar. However, analysis under offline SPE and DI approaches provided a larger amount of information as they reached lower MLQs. Offline-SPE provided the worst precision among all.
Materias Unesco
23 Química
3308 Ingeniería y Tecnología del Medio Ambiente
Palabras Clave
Contaminant of emerging concern
Microcontaminant
Swine manure
Fast analysis
Green chemistry
Large volume injection
ISSN
0026-265X
Revisión por pares
SI
Patrocinador
Junta de Castilla y León, y el programa EU-FEDER (CLU 2017-09),(CL-EI-2021-07),(UIC 071),(UIC 338),(INFRARED2018-UVA3).
Ministerio de Ciencia, Innovación y Universidades (proyectos CTQ2017-84006-C3-1-R y PID2020-113544RB-I00)
Ministerio de Ciencia, Innovación y Universidades (proyectos CTQ2017-84006-C3-1-R y PID2020-113544RB-I00)
Version del Editor
Propietario de los Derechos
© 2023 The Author(s)
Idioma
eng
Tipo de versión
info:eu-repo/semantics/publishedVersion
Derechos
openAccess
Collections
Files in this item
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional