Mostrar el registro sencillo del ítem

dc.contributor.authorDíez Montero, Cecilia
dc.contributor.authorLópez de la Rosa, Alberto
dc.contributor.authorLópez Miguel, Alberto 
dc.contributor.authorMaldonado López, Miguel José 
dc.date.accessioned2023-05-02T09:25:09Z
dc.date.available2023-05-02T09:25:09Z
dc.date.issued2023
dc.identifier.citationGraefe's Archive for Clinical and Experimental Ophthalmology, 2023.es
dc.identifier.issn0721-832Xes
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/59450
dc.descriptionProducción Científicaes
dc.description.abstractPurpose To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial length (AxL). Methods Anterior and posterior cortex and nucleus thickness of the crystalline lens, ACD, and AxL were measured using optical low-coherence reflectometry in cataractous and non-cataractous eyes. They were also classified into hyperopia, emme- tropia, myopia, and high myopia, depending on AxL; thus, eight subgroups were created. A minimum sample size of 44 eyes (of 44 patients) for each group was recruited. Linear models were fitted for the whole sample and each AxL subgroup to assess if there were differences in the relationships between the crystalline lens variables and ACD, including age as a covariate. Results Three hundred seventy cataract patients (237 females, 133 males) and 250 non-cataract controls (180 females, 70 males), aged 70.5 ± 9.4 and 41.9 ± 15.5 years, respectively, were recruited. The mean AxL, ACD, and LT for the cataractous and non-cataractous eyes were 23.90 ± 2.05, 24.11 ± 2.11, 2.64 ± 0.45, and 2.91 ± 0.49, 4.51 ± 0.38, 3.93 ± 0.44 mm, respec- tively. The inverse relationship of LT, anterior and posterior cortex, and nucleus thickness with ACD was not significantly (p ≥ 0.26) different between cataractous and non-cataractous eyes. Further subclassification of the sample depending on AxL showed that the inverse relationship between the posterior cortex and ACD was no longer significant (p > 0.05) for any non-cataractous AxL group. LT, anterior and posterior cortex, and nucleus thickness was not significantly (p ≥ 0.43) different between cataractous and non-cataractous eyes for the whole sample, and all AxL groups after adjusting for age. Conclusions The presence of cataracts does not modify the inverse relationship of the LT, anterior and posterior cortex, and nucleus with ACD. And this relationship does not seem to depend importantly on AxL. Besides, the possible differences in LT, anterior and posterior cortex, and nucleus between cataractous and non-cataractous eyes may not be caused by lens opacification, but possibly by the progressive lens growth due to aging.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherSpringeres
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subject.classificationLens thicknesses
dc.subject.classificationAnterior cortexes
dc.subject.classificationPosterior cortexes
dc.subject.classificationNucleus thicknesses
dc.subject.classificationAxial lengthes
dc.subject.classificationAnterior chamber depthes
dc.subject.classificationCataractes
dc.titleRelationship between the main components of the crystalline lens and the anterior chamber depth after cataract formationes
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2023 The Author(s)es
dc.identifier.doi10.1007/s00417-023-06080-7es
dc.relation.publisherversionhttps://link.springer.com/article/10.1007/s00417-023-06080-7es
dc.identifier.publicationtitleGraefe's Archive for Clinical and Experimental Ophthalmologyes
dc.peerreviewedSIes
dc.description.projectMinisterio de Economía y Competitividad (Instituto de Salud Carlos III) through Research Projects (RETICS RD16/008/0001)es
dc.description.projectPublicación en abierto financiada por el Consorcio de Bibliotecas Universitarias de Castilla y León (BUCLE), con cargo al Programa Operativo 2014ES16RFOP009 FEDER 2014-2020 DE CASTILLA Y LEÓN, Actuación:20007-CL - Apoyo Consorcio BUCLEes
dc.identifier.essn1435-702Xes
dc.rightsAtribución 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones
dc.subject.unesco32 Ciencias Médicases
dc.subject.unesco3201.09 Oftalmologíaes


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem