• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Stöbern

    Gesamter BestandBereicheErscheinungsdatumAutorenSchlagwortenTiteln

    Mein Benutzerkonto

    Einloggen

    Statistik

    Benutzungsstatistik

    Compartir

    Dokumentanzeige 
    •   UVaDOC Startseite
    • WISSENSCHAFTLICHE ARBEITEN
    • Institutos de Investigación
    • Instituto de las Tecnologías Avanzadas en la Producción (ITAP)
    • ITAP - Artículos de revista
    • Dokumentanzeige
    •   UVaDOC Startseite
    • WISSENSCHAFTLICHE ARBEITEN
    • Institutos de Investigación
    • Instituto de las Tecnologías Avanzadas en la Producción (ITAP)
    • ITAP - Artículos de revista
    • Dokumentanzeige
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/63594

    Título
    Interaction with a hand rehabilitation exoskeleton in EMG-driven bilateral therapy: Influence of visual biofeedback on the users’ performance
    Autor
    Cisnal De La Rica, AnaAutoridad UVA Orcid
    Gordaliza Pastor, PaulaAutoridad UVA
    Pérez Turiel, JavierAutoridad UVA Orcid
    Fraile Marinero, Juan CarlosAutoridad UVA Orcid
    Año del Documento
    2023
    Editorial
    MDPI
    Descripción
    Producción Científica
    Documento Fuente
    Sensors, 2023, Vol. 23, Nº. 4, 2048
    Zusammenfassung
    The effectiveness of EMG biofeedback with neurorehabilitation robotic platforms has not been previously addressed. The present work evaluates the influence of an EMG-based visual biofeedback on the user performance when performing EMG-driven bilateral exercises with a robotic hand exoskeleton. Eighteen healthy subjects were asked to perform 1-min randomly generated sequences of hand gestures (rest, open and close) in four different conditions resulting from the combination of using or not (1) EMG-based visual biofeedback and (2) kinesthetic feedback from the exoskeleton movement. The user performance in each test was measured by computing similarity between the target gestures and the recognized user gestures using the L2 distance. Statistically significant differences in the subject performance were found in the type of provided feedback (p-value 0.0124). Pairwise comparisons showed that the L2 distance was statistically significantly lower when only EMG-based visual feedback was present (2.89 ± 0.71) than with the presence of the kinesthetic feedback alone (3.43 ± 0.75, p-value = 0.0412) or the combination of both (3.39 ± 0.70, p-value = 0.0497). Hence, EMG-based visual feedback enables subjects to increase their control over the movement of the robotic platform by assessing their muscle activation in real time. This type of feedback could benefit patients in learning more quickly how to activate robot functions, increasing their motivation towards rehabilitation.
    Materias (normalizadas)
    Biofeedback
    Biorretroalimentación
    Biological control systems
    Sistemas de control biológico
    Biomedicine
    Electromyography
    Electromiografía
    Human robot interaction
    Rehabilitation technology
    Robotics
    Robotics in medicine
    Robótica
    Robotic exoskeletons
    Neuromuscular diseases - Treatment
    Enfermedades neuromusculares - Tratamiento
    Materias Unesco
    32 Ciencias Médicas
    6103.08 Rehabilitación
    3314 Tecnología Médica
    ISSN
    1424-8220
    Revisión por pares
    SI
    DOI
    10.3390/s23042048
    Patrocinador
    Ministerio de Ciencia e Innovación - (project RTC2019-007350-1)
    Consejería de Educación, Fondo Social Europeo, Gobierno Vasco - (BERC 2022-2025) y (project 3KIA (KK-2020/00049)
    Ministerio de Ciencia, Innovación y Universidades - (BCAM Severo Ochoa: SEV-2017-0718)
    Version del Editor
    https://www.mdpi.com/1424-8220/23/4/2048
    Propietario de los Derechos
    © 2023 The authors
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/63594
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Aparece en las colecciones
    • ITAP - Artículos de revista [53]
    Zur Langanzeige
    Dateien zu dieser Ressource
    Nombre:
    Interaction-with-a-Hand-Rehabilitation-Exoskeleton.pdf
    Tamaño:
    2.127Mb
    Formato:
    Adobe PDF
    Thumbnail
    Öffnen
    Atribución 4.0 InternacionalSolange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Atribución 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10