• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Parcourir

    Tout UVaDOCCommunautésPar date de publicationAuteursSujetsTitres

    Mon compte

    Ouvrir une session

    Statistiques

    Statistiques d'usage de visualisation

    Compartir

    Voir le document 
    •   Accueil de UVaDOC
    • PUBLICATIONS SCIENTIFIQUES
    • Departamentos
    • Dpto. Teoría de la Señal y Comunicaciones e Ingeniería Telemática
    • DEP71 - Artículos de revista
    • Voir le document
    •   Accueil de UVaDOC
    • PUBLICATIONS SCIENTIFIQUES
    • Departamentos
    • Dpto. Teoría de la Señal y Comunicaciones e Ingeniería Telemática
    • DEP71 - Artículos de revista
    • Voir le document
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/75371

    Título
    Computing thickness of irregularly-shaped thin walls using a locally semi-implicit scheme with extrapolation to solve the Laplace equation: Application to the right ventricle
    Autor
    Merino-Caviedes, Susana
    Martín-Fernández, Marcos
    Pérez Rodríguez, María TeresaAutoridad UVA
    Martín-Fernández, Miguel Ángel
    Filgueiras-Rama, David
    Simmross-Wattenberg, Federico
    Alberola-López, Carlos
    Año del Documento
    2024
    Descripción
    Producción Científica
    Documento Fuente
    Computers in Biology and Medicine, Febrero 2024, vol. 169, p. 107855.
    Résumé
    Cardiac Magnetic Resonance (CMR) Imaging is currently considered the gold standard imaging modality in cardiology. However, it is accompanied by a tradeoff between spatial resolution and acquisition time. Providing accurate measures of thin walls relative to the image resolution may prove challenging. One such anatomical structure is the cardiac right ventricle. Methods for measuring thickness of wall-like anatomical structures often rely on the Laplace equation to provide point-to-point correspondences between both boundaries. This work presents limex, a novel method to solve the Laplace equation using ghost nodes and providing extrapolated values, which is tested on three different datasets: a mathematical phantom, a set of biventricular segmentations from CMR images of ten pigs and the database used at the RV Segmentation Challenge held at MICCAI'12. Thickness measurements using the proposed methodology are more accurate than state-of-the-art methods, especially with the coarsest image resolutions, yielding mean L_1 norms of the error between 43.28% and 86.52% lower than the second-best methods on the different test datasets. It is also computationally affordable. Limex has outperformed other state-of-the-art methods in classifying RV myocardial segments by their thickness.
    Palabras Clave
    Laplace equation, Ghost Node Methods, Right Ventricle, Wall Thickness, Cardiac Magnetic Resonance
    ISSN
    0010-4825
    Revisión por pares
    SI
    DOI
    10.1016/j.compbiomed.2023.107855
    Patrocinador
    This work was supported in part by the spanish Agencia Estatal de Investigación, under Grants PID2020-115339RB-I00 and TED2021-130090B-I00, and by the company ESAOTE Ltd by grant 18IQBM.
    Version del Editor
    https://doi.org/10.1016/j.compbiomed.2023.107855
    Propietario de los Derechos
    Elsevier
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/75371
    Tipo de versión
    info:eu-repo/semantics/acceptedVersion
    Derechos
    restrictedAccess
    Aparece en las colecciones
    • DEP71 - Artículos de revista [358]
    Afficher la notice complète
    Fichier(s) constituant ce document
    Nombre:
    CIBM_RightVentricularThickness_UVaDOC.pdf
    Tamaño:
    6.381Mo
    Formato:
    Adobe PDF
    Descripción:
    Artículo Principal
    Thumbnail
    Voir/Ouvrir
    Attribution-NonCommercial-NoDerivatives 4.0 InternacionalExcepté là où spécifié autrement, la license de ce document est décrite en tant que Attribution-NonCommercial-NoDerivatives 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10