Show simple item record

dc.contributor.authorGarcía Escudero, Luis Ángel 
dc.contributor.authorDuque Pérez, Óscar 
dc.contributor.authorFernández Temprano, Miguel Alejandro 
dc.contributor.authorMoríñigo Sotelo, Daniel 
dc.date.accessioned2016-12-02T19:23:14Z
dc.date.available2016-12-02T19:23:14Z
dc.date.issued2016
dc.identifier.citationIEEE Transactions on Industry Applications, 2017, vol. 53, n. 3, p. 3076-3085.es
dc.identifier.issn0093-9994
dc.identifier.urihttp://uvadoc.uva.es/handle/10324/21441
dc.description.abstractA considerable amount of papers have been published in recent years proposing supervised classifiers to diagnose the health of a machine. The usual procedure with these classifiers is to train them using data acquired through controlled experiments, expecting them to perform well on new data, classifying correctly the condition of a motor. But, obviously, the new motor to be diagnosed cannot be the same that has been used during the training process; it may be a motor with different characteristics and fed from a completely different source. These different conditions between the training process and the testing one can deeply influence the diagnosis. To avoid these drawbacks, in this paper a new method is proposed which is based on robust statistical techniques applied in Quality Control applications. The proposed method is based on the online diagnosis of the operating motor and can detect deviations from the normal operational conditions. A robust approach has been implemented using high-breakdown statistical techniques which can reliably detect anomalous data that often cause an unexpected overestimation of the data variability, reducing the ability of standard procedures to detect faulty conditions in earlier stages. A case study is presented to prove the validity of the proposed approach. Motors of different characteristics, fed from the power line and several different inverters, are tested. Three different fault conditions are provoked, broken bar, a faulty bearing and mixed eccentricity. Experimental results prove that the proposed approach can detect incipient faults.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectStatisticses
dc.subjectFault detection
dc.subjectMotors
dc.subject.classificationDiagnostic expert systems induction motors
dc.subject.classificationmaintenance
dc.subject.classificationmonitoring
dc.subject.classificationquality control
dc.titleRobust detection of incipient faults in VSI-fed induction motors using quality control charts.es
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holder© 2016 IEEE
dc.identifier.doi10.1109/TIA.2016.2617300
dc.relation.publisherversionhttp://ieeexplore.ieee.org/document/7590081/
dc.peerreviewedSIes
dc.description.projectMINECO and FEDER program grants DPI2014-52842-P, MTM2015-71217-R, MTM2014-56235-C2-1-P
dc.description.projectConsejería de Educación de la Junta de Castilla y León under Grant VA212U13
dc.rightsAttribution 4.0 International
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersion